Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › 2019 Novel Coronavirus (COVID-19), NAA

2019 Novel Coronavirus (COVID-19), NAA: Labcorp test 139900

Labcorp test 139900, CPT 87635. Specimen: Oropharyngeal (OP) collection in viral transport medium, ESwab™, or saline.. Turnaround: 1 - 3 days.

2019 Novel Coronavirus (COVID-19), NAA is Labcorp test code 139900, billed with CPT 87635. Specimen: Oropharyngeal (OP) collection in viral transport medium, ESwab™, or saline.. Turnaround time: 1 - 3 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code139900
CPT87635
LOINC94500-6
SpecimenOropharyngeal (OP) collection in viral transport medium, ESwab™, or saline. Nasopharyngeal (NP) swabs also accepted in viral transport medium (discard OP swab included with viral transport medium), ESwab™, or saline. Anterior nasal swab in saline. OP or NP washes/aspirates in sterile cups. Bronchial washing or bronchoalveolar lavage (BAL) specimens in sterile cups.
Volume1.4 mL
Minimum volume1 mL ( Note: This volume does not allow for repeat testing.)
ContainerFor swabs in viral transport medium or ESwab™: Oropharyngeal (OP) samples: Swab included in viral transport medium or ESwab™ is acceptable for submission. Nasopharyngeal (NP) samples: Use separate NP swab submitted in viral transport medium (discard OP swab included with viral transport medium or ESwab™). Exact manufacturer of the swab and transport medium may vary with supply. Any swab of appropriate size and configuration with a synthetic tip can be used except for calcium alginate tips, swabs with preservatives, and swabs with wood shafts. Viral transport medium acceptable for collection of influenza specimens in 1 mL or 3 mL volumes can be used to transport swabs for COVID-19 testing. For swabs in saline: OP, NP or anterior nasal swabs may be placed in 1 to 3 mL of sterile saline (0.85 to 0.9%) in a sterile screw cap container. Do not use vacutainer or "pop-top" tubes. Any swab of appropriate size and configuration with a cotton or synthetic tip can be used except for calcium alginate tips, swabs in preservatives, and swabs with wood shafts. Sterile cups are acceptable for OP or NP washes/aspirates, bronchial washings, or bronchoalveolar lavage (BAL) specimens. Swab in saline in screw-top Vacuette Virus Stabilization Tube is acceptable.
Turnaround time1 - 3 days
Storage / transportFrozen at -20° C (preferred). Refrigerated specimens acceptable (if received for testing within 72 hours of collection). Room temperature swabs are acceptable (if received within 24 hours of collection).

Also known as: 2019 Novel Coronavirus; COVID-19; SARS-CoV-2

Use

Detection of SARS-CoV-2 to assist in the diagnosis of COVID-2019 infections.

Methodology

Nucleic Acid Amplification (NAA)

Collection instructions

To avoid delays in turnaround time when requesting multiple tests on frozen samples, please submit separate frozen specimens for each test requested.

Causes for rejection

Vacutainers and other "pop-top" tubes; cotton-tip swabs in UTM/VTM; swabs with calcium alginate; swabs with wooden shafts; refrigerated samples greater than 72 hours old; room temperature swabs greater than 24 hours old; improperly labeled, grossly contaminated, broken or leaking transport device; collection with substances inhibitory to PCR including heparin, hemoglobin, ethanol, EDTA concentrations >0.01M; specimens submitted in glass tubes/containers; dry swab without media; swabs in "molecular media" (such as PrimerStore MTM or other guanidine-containing media); Aptima swabs; swabs in gel-based, anaerobic, or charcoal media; 3D printed swabs; Hanks' balanced salt solution or specimens submitted without swabs

Special instructions

Please note: Labcorp does not currently collect specimens for this test. Patients for whom testing has been ordered should not be sent to a Labcorp location to have a specimen collected. Instead, an appropriate specimen should be collected at the health care facility where the patient was seen and the test was ordered. The specimen should be sent to Labcorp using standard procedures. Please note: It takes approximately 1 - 3 days from the date of pickup of a specimen for testing to the release of the test result to the health care provider. Test results are most typically reported electronically, which generally allows for faster delivery. This time frame can vary based on demand, the length of time to transport the specimen to Labcorp's test facilities, and the prioritization of the patients (as defined by heath care authorities and the White House Coronavirus Task Force, HHS and other health authorities). Labcorp is working continuously to support the needs of health care workers, patients, government, clients and other organizations, and expects capacity to continue to increase. We have been regularly tracking mutations of the virus throughout the pandemic to determine the impact it would have on our test sensitivity. To date, we have not seen any impact.

LOINC map

Result codeResult nameUnitsResult LOINC
139901SARS-CoV-2, NAA94500-6

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 87635

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation