Chlamydia pneumoniae, IgG and IgM: Labcorp test 138338

Labcorp test 138338, CPT 86631, 86632. Specimen: Serum. Turnaround: 2 - 4 days.

Chlamydia pneumoniae, IgG and IgM is Labcorp test code 138338, billed with CPT 86631, 86632. Specimen: Serum. Turnaround time: 2 - 4 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, ARUP Laboratories, Michigan Medicine Laboratories (MLabs).
LaboratoryLabcorp
CLIA number34D0655059
Test code138338
CPT86631; 86632
LOINC6913-8, 6914-6, 77166-7
SpecimenSerum
Volume1 mL
Minimum volume0.3 mL
ContainerRed-top tube or gel-barrier tube
Turnaround time2 - 4 days
Storage / transportRefrigerate. Per the package insert: Samples are stable at room temperature for eight hours. After eight hours, samples should be refrigerated at 2° to 8°C for up to 48 hours. After 48 hours, freeze samples at -20°C or colder.

Use

This test is intended for the qualitative detection and semi-quantitation of human serum IgM and IgG antibodies to Chlamydia pneumoniae to aid in the diagnosis of community-acquired pneumonia caused by Chlamydia pneumoniae in individuals presenting with pneumonia.

Methodology

Micro-immunofluorescence antibody (MIF) assay

Limitations

Results of this test are labeled for investigational purposes only by the assay's manufacturer. The performance characteristics of this assay have not been established by the manufacturer. The result should not be used for the treatment or for diagnostic purposes without confirmation of the diagnosis by another medically established diagnostic product or procedure. The performance characteristics were determined by Labcorp. All results must be correlated with clinical history, epidemiological data and other clinical data. The performance of this assay has not been established for diagnosing non-pneumonia diseases associated with Chlamydia pneumoniae (e.g., bronchitis, sinusitis, otitis,…

LOINC map

Result codeResult nameUnitsResult LOINC
139318Chlamydia pneumoniae IgG6913-8
139319Chlamydia pneumoniae IgM6914-6

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 86631, 86632

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation