Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Bladder Cancer FISH, Pathologist Review

Bladder Cancer FISH, Pathologist Review (Bladder Cancer Fish Pathologist Review): Labcorp test 130080

Labcorp test 130080, CPT 88120. Specimen: Urine. Turnaround: 4 - 5 days.

Bladder Cancer FISH, Pathologist Review is Labcorp test code 130080, billed with CPT 88120. Specimen: Urine. Turnaround time: 4 - 5 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code130080 (Bladder Cancer Fish Pathologist Review)
CPT88120
LOINC31208-2, 33511-7, 48767-8, 56030-0, 8251-1
SpecimenUrine
Volume50 mL urine mixed with preservative in TCC Monitoring kit
Minimum volume33 mL urine mixed with preservative in TCC Monitoring kit
ContainerTCC Monitoring kit (PeopleSoft item N° 44921). Other containers that are accepted, but not recommended: PreservCyt® vial, Cytology Special Studies Kit (PeopleSoft item N° 3203), or sterile urine container with Carbowax® fixative (two parts urine; one part fixative).
Turnaround time4 - 5 days
Storage / transportSpecimen should be refrigerated at 2°C to 8°C and shipped on cool packs. Do not freeze.

Also known as: Urothelial Carcinoma, FISH; UroVysion®, FISH

Use

The assay is designed to detect aneuploidy for chromosomes 3, 7, 17, and loss of the 9p21 locus via fluorescence in situ hybridization (FISH) in urine specimens from subjects with transitional cell carcinoma of the bladder. This assay does not detect other chromosomal or genetic alterations. Results are intended for use as a noninvasive method of monitoring for tumor recurrence in conjunction with cystoscopy in patients previously diagnosed with bladder cancer. The clinical interpretation of test results should be evaluated within the context of the patient's medical history and other diagnostic laboratory test results.

Methodology

Fluorescence in situ hybridization (including diagnostic interpretation by MD pathologist)

Collection instructions

Step 1: Use the large, open cup in the kit to collect the urine specimen. First void of the day is preferred. Ensure that the urine specimen reaches the minimum fill line of 33 mL. Step 2: Slowly pour urine into the smaller container to the maximum fill line of 90 mL. Step 3: Tighten the lid until you hear a click in order to prevent leakage.

Causes for rejection

Incorrect fixative; significant contamination with blood obscuring bacterial overgrowth; inadequate specimen cellularity

Special instructions

Specimens should be received at the laboratory within 72 hours postcollection for optimal testing. Specimens older than 72 hours will not be rejected; however, results not guaranteed. In these instances, clients should consider recollection if possible.

Limitations

Positive FISH results in the absence of other signs or symptoms of bladder cancer recurrence may be evidence of other urinary tract-related cancers (eg, ureter, urethra, renal, and/or prostate in males), and further patient follow-up may be helpful. Negative FISH results in the presence of other signs and symptoms of bladder cancer recurrence may need to be regarded as suspicious false-negative results; repeat testing may be indicated. Although the assay was designed to detect chromosome changes associated with most bladder cancers, there are some bladder cancers whose genetic changes are not targeted by this test.

LOINC map

Result codeResult nameUnitsResult LOINC
130018Bladder Cancer FISH Findings:56030-0
130019Specimen Type:31208-2
130034Specimen Description:33511-7
130035Case Comment:48767-8
130036Specimen Comment:8251-1

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 88120

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation