GlycA: Labcorp test 123850

Labcorp test 123850, CPT 0024U. Specimen: Serum, shipped refrigerated, or plasma. Turnaround: 3 - 6 days.

GlycA is Labcorp test code 123850, billed with CPT 0024U. Specimen: Serum, shipped refrigerated, or plasma. Turnaround time: 3 - 6 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC).
LaboratoryLabcorp
CLIA number34D0655059
Test code123850
CPT0024U
LOINC82730-3
SpecimenSerum, shipped refrigerated, or plasma
Volume1 mL
Minimum volume0.5 mL
ContainerPlain red-top tube (preferred); NMR LipoTube (black-and-yellow-top tube), lavender-top (EDTA-no gel) tube or green-top (heparin-no gel) tube is acceptable
Turnaround time3 - 6 days
Storage / transportRefrigerate; stable for 14 days. Stable at room temperature for 60 hours or frozen for 24 months. Freeze/thaw cycles: x3

Use

As an (1) aid in the identification and stratification of individuals at risk for future cardiovascular (CV) disease, (2) independent marker of prognosis for recurrent cardiovascular events in patients with stable coronary disease or acute coronary syndrome, (3) aid in the assessment of disease activity and risk of CV disease in adult Rheumatoid Arthritis (RA) and psoriasis patients, when used in conjunction with standard clinical assessment and for monitoring of anti-inflammatory treatment.

Methodology

Nuclear magnetic resonance (NMR)

Collection instructions

Collect specimen in plain red-top tube, which is the preferred specimen. Hold tube upright at room temperature for 45 minutes and allow to clot. Centrifuge specimen after clotting according to manufacturer's specifications. Transfer to a transport tube for storage at 2°C to 8°C until shipped. For NMR LipoTube (black-and-yellow-top tube), keep upright at room temperature for 30 minutes and allow to clot. Centrifuge at 1600 to 1800 xg for 10 to 15 minutes immediately after clotting. If the sample cannot be centrifuged immediately, it must be refrigerated at 2°C to 8°C and centrifuged within 24 hours of collection. The NMR tube should then be stored at 2°C to 8°C until shipped. Separate plasma from lavender-top (EDTA-no gel) tube or green-top (heparin-no gel) tube immediately after collection and transfer to a plastic transport tube for shipment to the laboratory. Do not open NMR LipoTube. Serum or plasma drawn in gel-barrier collection tubes other than the NMR LipoTube should not be used.

Patient preparation

Patient fasting is not necessary prior to draw.

Causes for rejection

Unspun LipoTube or unseparated plain red-top or EDTA tube; serum or plasma specimen drawn in gel-barrier collection tube other than the NMR LipoTube; hemolysis (may reduce GlycA concentrations more than 10%)

Reference range

GlycA Medical decision limit: • Low <400 μmol/L • High ≥400 μmol/L

Limitations

Measurements from EDTA plasma specimens are, on average, 3% to 5% lower than from serum samples. Measurements from NMR LipoTube specimens are, on average, 5% to 6% higher than from serum samples collected in red-top tubes. GlycA is an indicator for a wide range of disease processes and should not be interpreted without a complete clinical history. Recent medical events resulting in tissue injury, infections, or inflammation, which may cause elevated GlycA levels, should also be considered when interpreting results. Hemolysis may reduce GlycA concentrations more than 10%. This test was developed, and its performance characteristics determined, by LabCorp. It has not been cleared or approved…

LOINC map

Result codeResult nameUnitsResult LOINC
123851GlycAumol/L82730-3

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 0024U

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation