Oxidized Low-density Lipoprotein (OxLDL): Labcorp test 123023
Labcorp test 123023, CPT 83721. Specimen: Plasma (preferred) or serum (acceptable). Turnaround: 3 - 5 days.
Also known as: Oxidized LDL; OxLDL
Use
For the in vitro quantitative measurement of oxidized low density lipoproteins (oxidized LDL) in human serum or plasma. Measurement of oxidized LDL (oxLDL) has been incorporated into clinical practice in the diagnosis and treatment of lipid disorders (such as diabetes mellitus), atherosclerosis, and various liver and renal diseases, especially as it pertains to the evaluation of oxidative stress. Oxidized LDL-particles are considered to be an important driving factor in the pathophysiology of atherosclerosis and oxLDL measurement has been used to test the efficacy of CVD drugs (eg, statins) to reduce oxidative stress.
Methodology
Enzyme-linked immunoassay (ELISA)
Collection instructions
For plasma, draw blood into an EDTA tube and gently invert the tube 8 to 10 times to mix the anticoagulant. Centrifuge the tube, remove the stopper and draw off approximately / 3 of the upper plasma layer into a labeled transport tube using a transfer pipet bulb. Note: This ensures the buffy coat of white cells and red cells remain undisturbed. Plasma must be separated from cells within 45 minutes of venipuncture. Send plasma in a frozen plastic transport tube. To avoid delays in turnaround time when requesting multiple tests on frozen samples, please submit separate frozen specimens on each test requested.
Stability
| Temperature | Period |
|---|---|
| Room temperature | Unacceptable (stability provided by manufacturer or literature reference) |
| Refrigerated | Unacceptable (stability provided by manufacturer or literature reference) |
| Frozen | 2 years (stability provided by manufacturer or literature reference) |
| Freeze/thaw cycles | Stable x1 (stability provided by manufacturer or literature reference) |
Patient preparation
Overnight fasting is preferred.
Causes for rejection
Specimen other than EDTA plasma or serum; improper labeling; specimen not stored properly; specimen older than stability limits; hemolysis; lipemia; non-frozen sample received
Reference range
10–170 ng/mL
Limitations
Lipemic or hemolytic samples may give erroneous results and should not be used for analysis.
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|---|---|---|
| 123024 | Oxidized LDL | ng/mL | 54238-1 |
View this test on Labcorp's website → · Last checked 2026-11-29
Other tests billed with CPT 83721
- LDL Cholesterol (Direct)
- LDL Cholesterol, Direct
- LDL Cholesterol, Direct
- Lipid Panel, Extended
- Low-density Lipoprotein Cholesterol (Direct)
- Oxidized Low-density Lipoprotein (OxLDL)
Search the National Lab Test Directory · All Labcorp tests and CLIA locations