Metanephrines, Fractionated, Plasma Free: Labcorp test 121806
Labcorp test 121806, CPT 83835. Specimen: Plasma. Turnaround: 3 - 6 days.
Also known as: Metanephrine; Normetanephrine; Plasma Metanephrines; Quantitative Metanephrines
Test includes
Metanephrine; normetanephrine
Use
Evaluation of catecholamine-secreting tumors of the adrenal medulla (pheochromocytomas) and extra-adrenal sympathetic and para-sympathetic paragangliomas.
Methodology
Liquid chromatography/tandem mass spectrometry (LC/MS-MS)
Collection instructions
Draw blood in chilled lavender-top (EDTA) tube. Invert to mix with preservatives. Centrifuge and transfer the plasma to a labeled plastic transport tube. Refrigerate or freeze separated plasma immediately. Important: The patient should be in a fully recumbent position (lying down) for at least 20 minutes before and during sample collection.
Stability
| Temperature | Period |
|---|---|
| Room temperature | Unstable |
| Refrigerated | 14 days |
| Frozen | 14 days |
| Freeze/thaw cycles | Stable x3 |
Patient preparation
Patient should be fasting overnight (water and non-caffeinated soft drinks are permissible). Patient should avoid alcohol, coffee, tea, tobacco and strenuous exercise prior to collection. See Limitations section for more information about other potential causes of elevated metanephrines.
Reference range
Metanephrine, Pl Age Male Female All ages 0.0–88.0 0.0–88.0 Normetanephrine, Pl Age Male Female 0 to 4 y Not established Not established 5 to 11 y 0.0–165.9 0.0–148.0 12 to 19 y 0.0–150.8 0.0–150.8 20 to 40 y 0.0–210.1 0.0–210.1 41 to 50 y 0.0–218.9 0.0–218.9 51 to 60 y 0.0–244.0 0–244.0 61 to 80 y 0.0–285.2 0.0–285.2 >80 y 0.0–297.2 0.0–297.2 Adult reference intervals applied to free metanephrines were originally developed by Eisenhofer and coworkers and further validated in subsequent studies. Recognizing the potential deadly consequences of a missed diagnosis, cutoffs of reference were established to ensure optimum diagnostic sensitivity, with specificity a secondary consideration. Subjects fasted and abstained from caffeinated and decaffeinated beverages overnight. Plasma samples collected after at least 20 minutes of supine rest. For plasma metabolites, optimal performance was obtained using age-specific reference intervals for normetanephrine, and for metanephrine single cut-offs for males and females that were slightly above 99.5 percentiles contributed to optimized performance.
Special instructions
For those centers where sampling blood in the fully recumbent, supine position is not possible, testing for 24-hour urine metanephrines (Labcorp Test No. 004234) may be preferable.
Limitations
The low prevalence of PPGL combined with the limited diagnostic specificity of the metanephrine test means that false-positive results far outnumber true-positive results. As outlined in the Endocrine Society Guidelines, all patients with positive test results should receive appropriate follow-up according to the extent of increased values and clinical presentation of the patient. The nature of this follow-up is a matter of clinical judgment based on the pretest probability of tumor and the extent and pattern of increases in test results. Inappropriate sampling conditions, as well as a number of medications and foods, should be considered as potential causes of borderline elevations of…
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|---|---|---|
| 070013 | Normetanephrine, Pl | pg/mL | 2669-0 |
| 070023 | Metanephrine, Pl | pg/mL | 38494-1 |
View this test on Labcorp's website → · Last checked 2026-11-29
Other tests billed with CPT 83835
- Metanephrines and Normetanephrines, Plasma
- Metanephrines and Normetanephrines, Urine
- Metanephrines Fractionated by HPLC-MS/MS, Urine
- Metanephrines, Fractionated, Quantitative, 24-Hour Urine
- Metanephrines, Free Plasma
- Metanephrines, Pheochromocytoma Evaluation
- Metanephrines, Plasma (Free)
- Metanephrines, Urine 24 hour
- Metanephrines, Urine Random
Search the National Lab Test Directory · All Labcorp tests and CLIA locations
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation