Vitamin K1: Labcorp test 121200

Labcorp test 121200, CPT 84597. Specimen: Serum or plasma, protected from light. Turnaround: 4 - 6 days.

Vitamin K1 is Labcorp test code 121200, billed with CPT 84597. Specimen: Serum or plasma, protected from light. Turnaround time: 4 - 6 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, ARUP Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code121200
CPT84597
LOINC9622-2
SpecimenSerum or plasma, protected from light
Volume1.0 mL
Minimum volume0.5 mL ( Note: This volume does not allow for repeat testing.)
ContainerEDTA (lavender-top) plasma, preferred. Also acceptable are lithium heparin (green-top) plasma, gel-separated (SST) serum, and standard (red-top) serum. For amber plastic transport tube and amber-top, order Labcorp No. 23598.
Turnaround time4 - 6 days
Storage / transportSpecimens should be light-protected, and shipped at room temperature or refrigerated (preferred).

Also known as: Phylloquinone

Use

This test is used for the assessment of vitamin K deficiency. Vitamin K deficiency may be induced by obstructive liver disease, obstructive icterus, malabsorption due to celiac disease, pancreatitis, diarrhea, and antibiotic abuse; may be used to treat blood clotting disorders, bone metabolism disorders, and hemorrhagic disorders of newborns.

Methodology

Liquid chromatography/tandem mass spectrometry (LC/MS-MS)

Collection instructions

The blood is to be collected by venipuncture into a Vacutainer® blood collection tube and mixed immediately by gentle inversion at least six times to ensure adequate mixing. Allow serum samples to clot for at least 10 minutes. Separate plasma/serum from red cells by centrifugation. Protect from light. Transfer plasma/serum specimen to labeled amber plastic transport tube with amber stopper . For amber plastic transport tube and amber stopper, order Labcorp No. 23598.

Stability

TemperaturePeriod
Room temperature7 days
Refrigerated14 days
Frozen28 days
Freeze/thaw cyclesStable x3

Patient preparation

Patient should fast for 12 hours.

Causes for rejection

Receipt of mild or grossly lipemic specimen; receipt of grossly hemolyzed specimen; receipt of specimen not protected from light; receipt of specimen outside of stability; receipt of citrate plasma

Reference range

0.10 – 2.20 ng/mL

Limitations

Overnight (12-hour) patient fasting is required. Consumption of supplements or food with Vitamin K may elevate plasma concentrations of Vitamin K1 for testing. Although lipemia does not interfere with the analytical measurement of Vitamin K1 by this test, Vitamin K1 levels are correlated with lipoprotein concentrations. As such, all lipemic samples should be rejected given Vitamin K1 levels are expected to be elevated in lipemic specimens and prevent evaluation for Vitamin K1 insufficiency. This test was developed and its performance characteristics determined by Labcorp. It has not been cleared or approved by the Food and Drug Administration.

LOINC map

Result codeResult nameUnitsResult LOINC
121201Vitamin K1ng/mL9622-2

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 84597

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation