Labcorp test 121137, CPT 83521. Specimen: Serum. Turnaround: 1 - 3 days.

Free κ and λ Light Chains Plus Ratio, Quantitative is Labcorp test code 121137, billed with CPT 83521. Specimen: Serum. Turnaround time: 1 - 3 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Michigan Medicine Laboratories (MLabs), Cleveland Clinic Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code121137
CPT83521(x2)
LOINC33944-0, 36916-5, 48378-4, 57778-3
SpecimenSerum
Volume0.5 mL
Minimum volume0.2 mL
ContainerRed-top tube or gel-barrier tube
Turnaround time1 - 3 days
Storage / transportRefrigerate; samples are stable for 21 days at 2°C to 8°C. For longer storage, freeze at -20°C.

Also known as: Freelite®; Kappa Free Light Chains, Quantitative, Serum; Kappa:Lambda Free Light Chains Ratio, Quantitative, Serum; Kappa:Lambda Free Light Chains, Quantitative, Serum; Lambda Free Light Chains, Quantitative, Serum; Light Chains, Free κ and Free λ, Quantitative, Serum

Test includes

κ free light chain quantitation in serum; λ free light chain quantitation in serum; calculated κ:λ light chains ratio in serum

Use

Free light chain (FLC) results should be considered under the following categories and investigated appropriately (κ = kappa free light chain; λ = lambda free light chain). 1. Normal samples: Serum κ, λ, and κ:λ are all within the normal ranges. If accompanying serum electrophoretic tests are normal, it is most unlikely that the patient has a monoclonal gammopathy. 2. Abnormal κ:λ ratios: Support the diagnosis of a monoclonal gammopathy and require an appropriate tissue biopsy. Borderline elevated κ:λ ratios occur with renal impairment and may require appropriate renal function tests. 3. Low concentrations of κ, λ, or both: Indicate bone marrow function impairment. 4. Elevated…

Methodology

Turbidimetric

Collection instructions

Sample should be allowed to clot and the serum separated as soon as possible to prevent hemolysis. To avoid delays in turnaround time when requesting multiple tests on frozen samples, please submit separate frozen specimens for each test requested.

Causes for rejection

Microbially-contaminated specimen; specimen containing particulate matter; lipemic or hemolyzed specimen

Reference range

• Free κ light chains: 3.3−19.4 mg/L • Free λ light chains: 5.7−26.3 mg/L • κ:λ free light chain ratio: 0.26−1.65

Special instructions

Values obtained with different assay methods should not be used interchangeably in serial testing. It is recommended that only one assay method be used consistently to monitor each patient's course of therapy. This procedure does not provide serial monitoring; it is intended for one-time use only. If serial monitoring is required, please use the serial monitoring number 121155 to order.

LOINC map

Result codeResult nameUnitsResult LOINC
121138Free Kappa Lt Chains,Smg/L36916-5
121139Free Lambda Lt Chains,Smg/L33944-0
121141Kappa/Lambda Ratio,S48378-4

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 83521

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation