Free κ and λ Light Chains Plus Ratio, Quantitative: Labcorp test 121137
Labcorp test 121137, CPT 83521. Specimen: Serum. Turnaround: 1 - 3 days.
Also known as: Freelite®; Kappa Free Light Chains, Quantitative, Serum; Kappa:Lambda Free Light Chains Ratio, Quantitative, Serum; Kappa:Lambda Free Light Chains, Quantitative, Serum; Lambda Free Light Chains, Quantitative, Serum; Light Chains, Free κ and Free λ, Quantitative, Serum
Test includes
κ free light chain quantitation in serum; λ free light chain quantitation in serum; calculated κ:λ light chains ratio in serum
Use
Free light chain (FLC) results should be considered under the following categories and investigated appropriately (κ = kappa free light chain; λ = lambda free light chain). 1. Normal samples: Serum κ, λ, and κ:λ are all within the normal ranges. If accompanying serum electrophoretic tests are normal, it is most unlikely that the patient has a monoclonal gammopathy. 2. Abnormal κ:λ ratios: Support the diagnosis of a monoclonal gammopathy and require an appropriate tissue biopsy. Borderline elevated κ:λ ratios occur with renal impairment and may require appropriate renal function tests. 3. Low concentrations of κ, λ, or both: Indicate bone marrow function impairment. 4. Elevated…
Methodology
Turbidimetric
Collection instructions
Sample should be allowed to clot and the serum separated as soon as possible to prevent hemolysis. To avoid delays in turnaround time when requesting multiple tests on frozen samples, please submit separate frozen specimens for each test requested.
Causes for rejection
Microbially-contaminated specimen; specimen containing particulate matter; lipemic or hemolyzed specimen
Reference range
• Free κ light chains: 3.3−19.4 mg/L • Free λ light chains: 5.7−26.3 mg/L • κ:λ free light chain ratio: 0.26−1.65
Special instructions
Values obtained with different assay methods should not be used interchangeably in serial testing. It is recommended that only one assay method be used consistently to monitor each patient's course of therapy. This procedure does not provide serial monitoring; it is intended for one-time use only. If serial monitoring is required, please use the serial monitoring number 121155 to order.
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|---|---|---|
| 121138 | Free Kappa Lt Chains,S | mg/L | 36916-5 |
| 121139 | Free Lambda Lt Chains,S | mg/L | 33944-0 |
| 121141 | Kappa/Lambda Ratio,S | 48378-4 |
View this test on Labcorp's website → · Last checked 2026-11-29
Other tests billed with CPT 83521
- CSF Kappa Free Light Chains With Reflex to Oligoclonal Banding
- Free κ and λ Light Chains Plus Ratio, Quantitative (Serial Monitor)
- Free κ and λ Light Chains Plus Ratio, Quantitative, Urine
- Free κ and λ Light Chains Plus Ratio, Quantitative, Urine (Serial Monitor)
- Immunofixation (IFE), Serum, Protein Electrophoresis (PE), Serum, and Quantitative Free κ and λ Light Chains (FLC) Plus Ratio, Serum
- Immunoglobulin Free Light Chains, Serum
- Kappa Free Light Chains, CSF
- Kappa/Lambda Quantitative Free Light Chains with Ratio, Serum
- Kappa/Lambda, Free, Serum
- Monoclonal Gammopathy Evaluation
- Monoclonal Protein Study, Expanded Panel, Serum
- Monoclonal Protein with Immunoglobulins and Free Light Chains, serum
- Multiple Sclerosis (MS) Profile, Serum and CSF
- Protein Electrophoresis, Serum and Quantitative Free κ and λ Light Chains (FLC) Plus Ratio, Serum
- Free κ and λ Light Chains Plus Ratio, Quantitative
- Immunofixation (IFE), Serum, Protein Electrophoresis (PE), Serum, and Quantitative Free κ and λ Light Chains (FLC) Plus Ratio, Serum
Search the National Lab Test Directory · All Labcorp tests and CLIA locations
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation