Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Protein C, Functional

Protein C, Functional: Labcorp test 117705

Labcorp test 117705, CPT 85303. Specimen: Plasma, frozen. Turnaround: 2 - 3 days.

Protein C, Functional is Labcorp test code 117705, billed with CPT 85303. Specimen: Plasma, frozen. Turnaround time: 2 - 3 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, ARUP Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code117705
CPT85303
LOINC27818-4
SpecimenPlasma, frozen
Volume1 mL
ContainerBlue-top (sodium citrate) tube
Turnaround time2 - 3 days
Storage / transportFreeze.

Also known as: Functional Protein C; Protein C Activity (Chromogenic)

Use

This test is used for confirmation and characterization of protein C deficiency.

Methodology

Protein C in plasma is activated by a specific enzyme (protein C activator) from copperhead snake venom ( Agkistrodon contortrix ). The amount of activated protein C is determined. The resulting activated PC (Protein Ca) is determined as the rate of hydrolysis of a chromogenic substrate in a kinetic test by measuring the increase in absorbance at 405 nm.

Collection instructions

Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate. Evacuated collection tubes must be filled to completion to ensure a proper blood-to-anticoagulant ratio. The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples, except when the sample is collected using a winged (i.e., "butterfly") collection system. With a winged blood collection set a discard tube should be drawn first to account for the dead space of the tubing and prevent under-filling of the evacuated tube. When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternative anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.

Stability

TemperaturePeriod
Frozen28 days
Freeze/thaw cyclesStable x3

Patient preparation

Ideally, the patient should not be on anticoagulant therapy. Avoid warfarin (Coumadin®) therapy for two weeks prior to the test and heparin, direct Xa and thrombin inhibitor therapies for about three days prior to testing. Do not draw from an arm with a heparin lock or heparinized catheter.

Causes for rejection

Severe hemolysis; improper labeling; clotted specimen; specimen diluted with IV fluids; samples thawed in transit; improper sample type; sample out of stability

Reference range

Protein C, Functional Age Range 1 d 24–40% 3 d 24–51% 1 to 11 m 28–124% 1 to 5 y 50–134% 6 to 10 y 64–125% 11 to 16 y 59–112% >16 y 77–150%

Special instructions

If the patient's hematocrit exceeds 55%, the volume of citrate in the collection tube must be adjusted. Refer to Coagulation Collection Procedures for directions.

Limitations

Individuals with heterozygous PC deficiency may have low normal PC levels. Treatment with warfarin decreases the levels of vitamin K-dependent factors including PC. PC levels start to drop after six hours of warfarin treatment and do not regain pretreatment levels until generally two weeks after cessation of therapy. Elevated factor VIII levels, as can be seen in acute phase reaction, can normalize the aPTT and effectively reduce PC levels. PC levels can be falsely low in patients with the factor V Leiden mutation. PC levels can become depleted as the result of activation of coagulation limiting the utility of testing for congenital PC deficiency during the immediate convalescent period…

LOINC map

Result codeResult nameUnitsResult LOINC
117705Protein C-Functional%27818-4

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 85303

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation