High Molecular Weight Kininogen (HMWK): Labcorp test 117359
Labcorp test 117359, CPT 85293. Specimen: Plasma, frozen. Turnaround: 4 - 8 days.
Also known as: Fitzgerald Factor; HMWK
Use
This test is used to measure the level of high molecular weight kininogen (HMWK) in plasma.
Methodology
Clot-based
Collection instructions
Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate. Evacuated collection tubes must be filled to completion to ensure a proper blood to anticoagulant ratio. The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples, except when using a winged blood collection device (i.e., "butterfly"), in which case a discard tube should be used. When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternate anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Centrifuge and carefully remove the plasma using a plastic transfer pipette, being careful not to disturb the cells. Transfer the plasma into a Labcorp PP transpak frozen purple tube with screw cap (Labcorp No. 49482). Freeze immediately and maintain frozen until tested. To avoid delays in turnaround time when requesting multiple tests on frozen samples, please submit separate frozen specimens for each test requested . Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.
Patient preparation
Do not draw from an arm with a heparin lock or heparinized catheter.
Reference range
71–165%
Limitations
Plasmas deficient in FXII may give falsely low results. Lupus anticoagulants and other non-specific factor inhibitors may also interfere with this assay. Heparin, direct Xa or thrombin inhibitor therapy may have an effect on factor assays. This test was developed and its performance characteristics determined by Labcorp. It has not been cleared or approved by the Food and Drug Administration.
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|---|---|---|
| 117360 | HMWK | % | 52754-9 |
View this test on Labcorp's website → · Last checked 2026-11-29
Other tests billed with CPT 85293
- Contact Factor Evaluation Profile
- High Molecular Weight Kininogen
- High Molecular Weight Kininogen (HMWK), Plasma
- High Molecular Weight Kininogen
Search the National Lab Test Directory · All Labcorp tests and CLIA locations
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation