Sound Lab Consultants › National Lab Test Directory › Labcorp › Epstein-Barr Virus (EBV) Antibodies to Viral Capsid Antigen (VCA), IgG

Epstein-Barr Virus (EBV) Antibodies to Viral Capsid Antigen (VCA), IgG: Labcorp test 096230

Labcorp test 096230, CPT 86665. Specimen: Serum. Turnaround: 1 - 2 days.

Epstein-Barr Virus (EBV) Antibodies to Viral Capsid Antigen (VCA), IgG is Labcorp test code 096230, billed with CPT 86665. Specimen: Serum. Turnaround time: 1 - 2 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, Michigan Medicine Laboratories (MLabs), ARUP Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code096230
CPT86665
LOINC5157-3
SpecimenSerum
Volume0.5 mL
Minimum volume0.2 mL
ContainerRed-top tube or gel-barrier tube
Turnaround time1 - 2 days
Storage / transportRoom temperature

Also known as: EBV-VCA Antibodies, IgG

Use

Differential diagnosis of infectious mononucleosis. VCA IgG antibodies appear early in EBV infection and titers peak between 2-4 weeks after the appearance of symptoms. IgG levels decline slightly but persist for life. The presence of VCA IgG antibodies in healthy individuals indicates immunological exposure to EBV either as silent primary infection or past exposure. Because of the complex relationship that exists between the EBV virus/host reaction and clinical manifestation, tracking of EBV antibody patterns may assist in diagnosis of EBV infection. Individual levels of specific antibodies are not necessarily indicative of disease state but can be of diagnostic significance when tracked…

Methodology

Chemiluminescent immunoassay (CLIA)

Stability

TemperaturePeriod
Room temperature14 days
Refrigerated14 days
Frozen14 days
Freeze/thaw cyclesStable x4

Causes for rejection

Hemolysis; lipemia; grossly icteric; visible particulate matter; gross bacterial contamination

Reference range

• Negative: <18.0 U/mL • Equivocal: 18.0−21.9 U/mL • Positive: >21.9 U/mL

Limitations

The results for this test are not by themselves diagnostic and should be considered in association with other clinical data and patient symptoms. This test is intended for qualitative determination only. The numeric value of the final result above the cutoff is not indicative of the amount of EBV-VCA antibody.

LOINC map

Result codeResult nameUnitsResult LOINC
096235EBV Ab VCA, IgGU/mL5157-3

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 86665

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation