Factor XIII Activity: Labcorp test 086340
Labcorp test 086340, CPT 85290. Specimen: Plasma, frozen. Turnaround: 4 - 6 days.
Use
This test is used to measure the level of factor XIII activity in citrate plasma.
Methodology
FXIII contained in the sample is converted by the action of thrombin into FXIIIa. Fibrin formed by thrombin also accelerates this reaction. Fibrinogen is not removed prior to testing since this would cause a loss of FXIII. Instead, fibrin produced by the action of thrombin is prevented from forming clots by an aggregation inhibiting peptide and held in solution. FXIIIa cross-links a specific peptide substrate to glycine ethyl ester, thereby releasing ammonia. The ammonia released is then determined in a parallel enzymatic reaction. The decrease in NADH is measured by monitoring the absorbance at 340 nm.
Collection instructions
Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate. Evacuated collection tubes must be filled to completion to ensure a proper blood-to-anticoagulant ratio. The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples unless the sample is collected using a winged (butterfly) collection system. With a winged blood collection set, a discard tube should be drawn first to account for the dead space of the tubing and prevent under-filling of the evacuated tube. When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternative anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.
Reference range
43–148%
Special instructions
If the patient's hematocrit exceeds 55%, the volume of citrate in the collection tube must be adjusted. Refer to Coagulation Collection Procedures for directions.
Limitations
This test was developed and its performance characteristics determined by Labcorp. It has not been cleared or approved by the Food and Drug Administration.
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|---|---|---|
| 086341 | Factor XIII Activity | % | 27815-0 |
View this test on Labcorp's website → · Last checked 2026-11-29
Other tests billed with CPT 85290
Search the National Lab Test Directory · All Labcorp tests and CLIA locations
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation