Factor XIII: Labcorp test 086330
Labcorp test 086330, CPT 85291. Specimen: Plasma, frozen. Turnaround: 3 - 4 days.
Also known as: Factor XIII, Qualitative; Fibrin Stabilizing Factor
Use
This is a screening assay and will detect homozygous deficiency of factor XIII.
Methodology
Clot solubility. The plasma is treated with thrombin to induce clot formation and the clot is transferred to a 5 molar urea solution. Clots from individuals with normal factor XIII levels are stable for at least 24 hours while clots from factor XIII deficient individuals will dissolve rapidly.
Collection instructions
Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate. Evacuated collection tubes must be filled to completion to ensure a proper blood-to-anticoagulant ratio. The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples unless the sample is collected using a winged (butterfly) collection system. With a winged blood collection set a discard tube should be drawn first to account for the dead space of the tubing and prevent under-filling of the evacuated tube. When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternative anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. To avoid delays in turnaround time when requesting multiple tests on frozen samples, please submit separate frozen specimens for each test requested . Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.
Patient preparation
Avoid warfarin (Coumadin®) therapy for two weeks and heparin therapy for two days prior to the test. Do not draw from an arm with a heparin lock or heparinized catheter.
Causes for rejection
Gross hemolysis; clotted specimen; frozen specimen thawed in transit; improper labeling
Reference range
Normal
Special instructions
If the patient's hematocrit exceeds 55%, the volume of citrate in the collection tube must be adjusted. Refer to Coagulation Collection Procedures for directions.
Limitations
This assay is a screening assay only. It will only be abnormal when factor XIII levels are less than 1% to 2%. To determine FXIII activity, a quantitative functional FXIII assay is recommended.
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|---|---|---|
| 086330 | Factor XIII | 3241-7 |
View this test on Labcorp's website → · Last checked 2026-11-29
Other tests billed with CPT 85291
Search the National Lab Test Directory · All Labcorp tests and CLIA locations
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation