Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Factor XIII

Factor XIII: Labcorp test 086330

Labcorp test 086330, CPT 85291. Specimen: Plasma, frozen. Turnaround: 3 - 4 days.

Factor XIII is Labcorp test code 086330, billed with CPT 85291. Specimen: Plasma, frozen. Turnaround time: 3 - 4 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code086330
CPT85291
LOINC3241-7
SpecimenPlasma, frozen
Volume1 mL
ContainerBlue-top (sodium citrate) tube
Turnaround time3 - 4 days
Storage / transportFreeze.

Also known as: Factor XIII, Qualitative; Fibrin Stabilizing Factor

Use

This is a screening assay and will detect homozygous deficiency of factor XIII.

Methodology

Clot solubility. The plasma is treated with thrombin to induce clot formation and the clot is transferred to a 5 molar urea solution. Clots from individuals with normal factor XIII levels are stable for at least 24 hours while clots from factor XIII deficient individuals will dissolve rapidly.

Collection instructions

Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate. Evacuated collection tubes must be filled to completion to ensure a proper blood-to-anticoagulant ratio. The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples unless the sample is collected using a winged (butterfly) collection system. With a winged blood collection set a discard tube should be drawn first to account for the dead space of the tubing and prevent under-filling of the evacuated tube. When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternative anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. To avoid delays in turnaround time when requesting multiple tests on frozen samples, please submit separate frozen specimens for each test requested . Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.

Patient preparation

Avoid warfarin (Coumadin®) therapy for two weeks and heparin therapy for two days prior to the test. Do not draw from an arm with a heparin lock or heparinized catheter.

Causes for rejection

Gross hemolysis; clotted specimen; frozen specimen thawed in transit; improper labeling

Reference range

Normal

Special instructions

If the patient's hematocrit exceeds 55%, the volume of citrate in the collection tube must be adjusted. Refer to Coagulation Collection Procedures for directions.

Limitations

This assay is a screening assay only. It will only be abnormal when factor XIII levels are less than 1% to 2%. To determine FXIII activity, a quantitative functional FXIII assay is recommended.

LOINC map

Result codeResult nameUnitsResult LOINC
086330Factor XIII3241-7

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 85291

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation