Factor V Activity: Labcorp test 086249

Labcorp test 086249, CPT 85220. Specimen: Plasma, frozen. Turnaround: 2 - 3 days.

Factor V Activity is Labcorp test code 086249, billed with CPT 85220. Specimen: Plasma, frozen. Turnaround time: 2 - 3 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, ARUP Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code086249
CPT85220
LOINC3193-0
SpecimenPlasma, frozen
Volume1 mL
ContainerBlue-top (sodium citrate) tube
Turnaround time2 - 3 days
Storage / transportFreeze.

Also known as: Proaccelerin

Use

This test is used to evaluate an isolated prolonged PT or for evaluation when both the aPTT and PT are prolonged and to assess factor V activity level.

Methodology

The assay consists of the measurement of the clotting time in a system in which all the factors are present and in excess except factor V, which is derived from the sample being tested. Testing coagulation factor activities requires that three dilutions be assayed and analyzed to produce a single result. The slope of the line created by plotting measured factor concentration against sample dilution is evaluated to discern the presence of inhibitors giving rise to nonparallelism.Moreover, samples producing results on initial dilution falling outside the analytic measurement range of the assay are tested at additional dilutions to produce reportable results.

Collection instructions

Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate. Evacuated collection tubes must be filled to completion to ensure a proper blood-to-anticoagulant ratio. The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples unless the sample is collected using a winged (butterfly) collection system. With a winged blood collection set a discard tube should be drawn first to account for the dead space of the tubing and prevent under-filling of the evacuated tube. When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternative anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.

Stability

TemperaturePeriod
Frozen28 days
Freeze/thaw cyclesStable x3

Patient preparation

Ideally, the patient should not be on anticoagulant therapy. Avoid warfarin (Coumadin®) therapy for two weeks prior to the test and heparin, direct Xa and thrombin inhibitor therapies for about three days prior to testing. Do not draw from an arm with a heparin lock or heparinized catheter.

Causes for rejection

Severe hemolysis; improper labeling; clotted specimen; specimen diluted with IV fluids; samples thawed in transit; improper sample type; sample out of stability

Reference range

‘Factor V Activity Age Range 1 d 64–103% 3 d 92–154% 1 to 11 m 94–141% 1 to 5 y 67–127% 6 to 10 y 56–141% 11 to 16 y 67–141% >16 y 64–166%

Special instructions

If the patient's hematocrit exceeds 55%, the volume of citrate in the collection tube must be adjusted. Refer to Coagulation Collection Procedures for directions.

Limitations

This test is not used for the diagnosis of factor V Leiden mutation. Direct Xa or thrombin inhibitor therapy may cause factitiously low results.

LOINC map

Result codeResult nameUnitsResult LOINC
086249Factor V Activity%3193-0

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 85220

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation