Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Human Epididymis Protein 4

Human Epididymis Protein 4: Labcorp test 081700

Labcorp test 081700, CPT 86305. Specimen: Serum. Turnaround: 1 - 3 days.

Human Epididymis Protein 4 is Labcorp test code 081700, billed with CPT 86305. Specimen: Serum. Turnaround time: 1 - 3 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, Michigan Medicine Laboratories (MLabs), ARUP Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code081700
CPT86305
LOINC55180-4
SpecimenSerum
Volume0.8 mL
Minimum volume0.4 mL ( Note: This volume does not allow for repeat testing.)
ContainerRed-top tube or gel-barrier tube
Turnaround time1 - 3 days
Storage / transportRefrigerate

Use

The assay is used as an aid in monitoring recurrence or progressive disease in patients with epithelial ovarian cancer. Serial testing for patient HE4 assay values should be used in conjunction with other clinical findings used for monitoring ovarian cancer.

Methodology

Electrochemiluminescence Immunoassay (ECLIA)

Collection instructions

If red-top tube is used, transfer separated serum to a plastic transport tube.

Stability

TemperaturePeriod
Room temperature5 days
Refrigerated14 days
Frozen14 days
Freeze/thaw cyclesStable x3

Patient preparation

No special patient preparations are required.

Causes for rejection

Nonserum sample received

Reference range

Gender Range (pmol/L) Male Not Established Female Age 0 to 39 years 0.0 – 61.2 40 to 49 years 0.0 – 63.6 50 to 59 years 0.0 – 105.2 60 to 69 years 0.0 – 96.5 >69 years 0.0 – 96.9 The distribution of HE4 levels determined in 1147 specimens is shown in the table. Distribution of HE4 Assay Values Number of Subjects 0−150 pMol 150.1−300 pMol 300.1−500 pMol >500 pMol Apparently Healthy Female (premenopausal) Female (postmenopausal) Benign Conditions Pregnancy Benign gynecological disease Other benign disease Hypertension/CHF Cancer Ovarian cancer Breast cancer Lung cancer Endometrial cancer Gastrointestinal cancer *In this study, 94.4% of the healthy female subjects had an HE4 assay value ≤150 pMol. Monitoring of disease status in patients diagnosed with ovarian cancer. The effectiveness of the HE4 EIA as an aid in monitoring of disease status in ovarian cancer patients was determined by assessing changes in HE4 levels in serial serum samples from 80 patients compared to changes in disease status. A study involving a total of 354 pairs of observations was undertaken with an average number of 4.4 observations per patient. A positive change in HE4 was defined as an increase in the value that was at least 25% greater than the previous value of the test. This level of change takes into account the variability of the assay and the biological variability. Sixty percent or 76/126 of the patient samples with a positive change correlated with the disease progression, while 75% or 171/228 of the patient serial samples with no significant change in HE4 value correlated with no progression. The total concordance was 70% or 247/354. The following table presents the data in a 2 x 2 format. Change in Disease State per Sequential Pair Increase in HE4 Concentration Progression No Progression Total >25% ≤25% Total The following table shows the resulting sensitivities and specificities of the HE4 EIA compared to the disease status at various changes in HE4 EIA concentrations. • Sensitivity is represented as a concordance of the HE4 EIA to progression of disease. • Specificity is represented as a concordance of the HE4 EIA to no progression of disease. Percent Change In HE4 Concentration (%) Sensitivity (%) Specificity (%)

Special instructions

Values obtained with different assay methods should not be used interchangeably in serial testing. It is recommended that only one assay method be used consistently to monitor each patient's course of therapy. This procedure does not provide serial monitoring; it is intended for one-time use only. If serial monitoring is required, please order test 481700 . This test may exhibit interference when sample is collected from a person who is consuming a supplement with a high dose of biotin (also termed as vitamin B7 or B8, vitamin H, or coenzyme R). It is recommended to ask all patients who may be indicated for this test about biotin supplementation. Patients should be cautioned to stop biotin consumption at least 72 hours prior to the collection of a sample.

Limitations

The HE4 assay should not be used as a cancer screening test. HE4 levels tend to be higher in older women and in women who began menstruating at an older age, but these affects are small. Falsely elevated or depressed values of HE4 may occur in samples containing human antimouse antibodies. Levels of HE4 within the reference range do not preclude the presence of cancer, nor are elevated results an absolute indication of malignancy; thus, HE4 should not be used for cancer screening.HE4 should not be used for monitoring patients with mucinous or germ cell ovarian cancer. Results should be interpreted in conjunction with other clinical and laboratory findings. The measured HE4 value of a…

LOINC map

Result codeResult nameUnitsResult LOINC
081750HE4pmol/L55180-4

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 86305

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation