Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Nickel, Plasma

Nickel, Plasma: Labcorp test 071571

Labcorp test 071571, CPT 83885. Specimen: Plasma. Turnaround: 2 - 4 days.

Nickel, Plasma is Labcorp test code 071571, billed with CPT 83885. Specimen: Plasma. Turnaround time: 2 - 4 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Michigan Medicine Laboratories (MLabs), ARUP Laboratories, Cleveland Clinic Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code071571
CPT83885
LOINC5702-6
SpecimenPlasma
Volume2 mL
Minimum volume0.6 mL
ContainerRoyal blue-top (EDTA) tube
Turnaround time2 - 4 days
Storage / transportMaintain specimen at room temperature.

Use

Monitor exposure to nickel

Methodology

Inductively coupled plasma/mass spectrometry (ICP/MS)

Collection instructions

Separate plasma immediately after the collection, and transfer to a certified metal-free transport tube (PeopleSoft No. 111166) for shipment to the laboratory.

Stability

TemperaturePeriod
Room temperature14 days
Refrigerated14 days
Frozen14 days
Freeze/thaw cyclesStable x3

Causes for rejection

Certified metal-free plastic transport tube not submitted

Reference range

• Environmental exposure: 0.6−7.5 μg/L • Occupational exposure: Levels of 3.0−11.0 μg/L may be seen in refinery workers.

Limitations

This test was developed and its performance characteristics determined by LabCorp. It has not been cleared or approved by the Food and Drug Administration.

LOINC map

Result codeResult nameUnitsResult LOINC
071571Nickel, Plasmaug/L5702-6

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 83885

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.