Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Aluminum, Serum or Plasma

Aluminum, Serum or Plasma: Labcorp test 071548

Labcorp test 071548, CPT 82108. Specimen: Serum or plasma. Turnaround: 2 - 4 days.

Aluminum, Serum or Plasma is Labcorp test code 071548, billed with CPT 82108. Specimen: Serum or plasma. Turnaround time: 2 - 4 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, ARUP Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code071548
CPT82108
LOINC5574-9
SpecimenSerum or plasma
Volume7 mL
Minimum volume0.6 mL
ContainerRoyal blue-top (EDTA) tube or royal blue-top without EDTA
Turnaround time2 - 4 days
Storage / transportMaintain specimen at room temperature.

Use

Monitor patients for prior and ongoing exposure to aluminum. Patients at risk include: • Infants on parenteral fluids, particularly parenteral nutrition • Burn patients through administration of intravenous albumin, particularly with coexisting renal failure • Adult and pediatric patients with chronic renal failure who accumulate aluminum readily from medications and dialysate • Adult parenteral nutrition patients (less so, recently) • Patients with industrial exposure Monitor dialysate and water to prepare dialysate to prevent aluminum toxicity in dialysis patients.

Methodology

Inductively coupled plasma/mass spectrometry (ICP/MS)

Collection instructions

Separate serum or plasma immediately after the collection, and transfer to a certified metal-free transport tube (PeopleSoft No. 111166) for shipment to the laboratory.

Stability

TemperaturePeriod
Room temperature14 days
Refrigerated14 days
Frozen14 days
Freeze/thaw cyclesStable x3

Causes for rejection

Royal blue-top tube not used in specimen collection; certified metal-free plastic transport tube not submitted

Reference range

Environmental exposure: 0−9 μg/L; patients on dialysis: <40 μg/L

Limitations

Serum levels rise and fall after each dose of aluminum-containing phosphate binder or sucralfate. If renal function is normal, renal clearance of aluminum is prompt, with urine levels rising quickly after a course of aluminum-containing antacid is begun, and with levels persisting elevated for over a week. Urine levels rise after a dose of deferoxamine given for any reason. The degree of rise in serum aluminum after deferoxamine is regarded as reflecting total body aluminum burden. This test was developed and its performance characteristics determined by LabCorp. It has not been cleared or approved by the Food and Drug Administration.

LOINC map

Result codeResult nameUnitsResult LOINC
071548Aluminum, Plasma/Serumug/L5574-9

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 82108

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation