Aluminum, Serum or Plasma: Labcorp test 071548
Labcorp test 071548, CPT 82108. Specimen: Serum or plasma. Turnaround: 2 - 4 days.
Use
Monitor patients for prior and ongoing exposure to aluminum. Patients at risk include: • Infants on parenteral fluids, particularly parenteral nutrition • Burn patients through administration of intravenous albumin, particularly with coexisting renal failure • Adult and pediatric patients with chronic renal failure who accumulate aluminum readily from medications and dialysate • Adult parenteral nutrition patients (less so, recently) • Patients with industrial exposure Monitor dialysate and water to prepare dialysate to prevent aluminum toxicity in dialysis patients.
Methodology
Inductively coupled plasma/mass spectrometry (ICP/MS)
Collection instructions
Separate serum or plasma immediately after the collection, and transfer to a certified metal-free transport tube (PeopleSoft No. 111166) for shipment to the laboratory.
Stability
| Temperature | Period |
|---|---|
| Room temperature | 14 days |
| Refrigerated | 14 days |
| Frozen | 14 days |
| Freeze/thaw cycles | Stable x3 |
Causes for rejection
Royal blue-top tube not used in specimen collection; certified metal-free plastic transport tube not submitted
Reference range
Environmental exposure: 0−9 μg/L; patients on dialysis: <40 μg/L
Limitations
Serum levels rise and fall after each dose of aluminum-containing phosphate binder or sucralfate. If renal function is normal, renal clearance of aluminum is prompt, with urine levels rising quickly after a course of aluminum-containing antacid is begun, and with levels persisting elevated for over a week. Urine levels rise after a dose of deferoxamine given for any reason. The degree of rise in serum aluminum after deferoxamine is regarded as reflecting total body aluminum burden. This test was developed and its performance characteristics determined by LabCorp. It has not been cleared or approved by the Food and Drug Administration.
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|---|---|---|
| 071548 | Aluminum, Plasma/Serum | ug/L | 5574-9 |
View this test on Labcorp's website → · Last checked 2026-11-29
Other tests billed with CPT 82108
Search the National Lab Test Directory · All Labcorp tests and CLIA locations