Chromosome Analysis, Amniotic Fluid With Reflex to SNP Microarray (Reveal®) (Women's Health): Labcorp test 052104
Labcorp test 052104. Specimen: Amniotic fluid, fetal urine or cystic hygroma fluid. Turnaround: 7 - 11 days.
Also known as: Karyotype, Amniotic Fluid With Reflex to Microarray
Use
The chromosome analysis determines fetal karyotype. A normal chromosome analysis will reflex to a high-resolution SNP microarray analysis targeting 2.8 million copy-number and allele-specific genome sites. The SNP assay will detect chromosomal imbalances that could be associated with developmental delay/congenital anomalies. It provides possible detection of uniparental disomy of any chromosome, the percent and location of homozygosity, including the degree of identity by descent.
Methodology
In situ cell culturing of amniocytes to investigate numerical and/or structural chromosome abnormalities. A normal chromosome analysis will reflex to SNP microarray analysis using the Cytoscan® HD Accel platform which uses 743,000 SNP probes and 2,029,441 NPCN probes with a median spacing of 0.818 kb.
Collection instructions
Discard first 2 mL of fluid aspirated to avoid maternal cell contamination. Specimen is collected in a 20 mL sterile syringe and transferred aseptically to sterile tubes to be transported to Labcorp. Test request form is completed and accompanies specimen and miscellaneous slip to the laboratory. Samples from twin (multiple) pregnancies should be appropriately labeled and placed in separate transport containers with a separate request form for each twin. Rubber stopper and/or frozen specimen cannot be processed.
Patient preparation
The patient preferably should have had ultrasound studies (to verify fetal life, detect multiple gestation, confirm gestational age, localize placenta).
Causes for rejection
Upon receipt, suitability of specimen will be determined by the Cytogenetics laboratory.
Special instructions
Pertinent medical findings must accompany request. If prior NIPT studies have been performed, include copy of the report. In the case of a reflex to microarray, concurrent maternal contamination (MCC) studies are required; submit maternal blood (EDTA) using Maternal Cell Contamination [511402] .
Limitations
Although the overall culture success rate is reported as >99%, culture failure can result. Reasons include (but are not limited to) lack of amniocytes in the fluid and contamination of the fluid with bacteria or yeast. For the SNP assay it does not detect balanced rearrangements, low-level mosaicism (<10%), marker chromosomes that only contain heterochromatin or tetraploidy. This test was developed and its performance characteristics determined by Labcorp. It has not been cleared or approved by the Food and Drug Administration.
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|---|---|---|
| 052138 | Cells Counted | 64095-3 | |
| 052139 | Colonies | 64096-1 | |
| 052140 | Cells Analyzed | 64092-0 | |
| 052141 | Cells Karyotyped | 64091-2 | |
| 052143 | GTG Band Resolution Achieved | 64093-8 |
View this test on Labcorp's website → · Last checked 2026-11-29