Labcorp test 052040. Specimen: Amniotic fluid, fetal urine or cystic hygroma fluid. Turnaround: 9 - 12 days.

Chromosome Analysis, Amniotic Fluid is Labcorp test code 052040. Specimen: Amniotic fluid, fetal urine or cystic hygroma fluid. Turnaround time: 9 - 12 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC).
LaboratoryLabcorp
CLIA number34D0655059
Test code052040
CPTContact CPT coding department at 800-222-7566, ext 6-8400.
LOINC62386-8, 64091-2, 64092-0, 64093-8, 64095-3, 64096-1
SpecimenAmniotic fluid, fetal urine or cystic hygroma fluid
Volume15-20 mL (20-30 mL for early amniocentesis)
Minimum volume5 mL (minimum volume may delay results due to fewer cells available for culture)
ContainerSterile plastic conical tube
Turnaround time9 - 12 days
Storage / transportMaintain specimen at room temperature. Do not freeze.

Also known as: Karyotype, Amniotic Fluid

Test includes

15 to 20 mitotic spreads counted from separate in situ colonies; two banded karyotypes prepared

Use

The test determines fetal karyotype. The test allows prenatal detection of chromosomal rearrangements, aneuploidy, or mosaicism. Such groups include women who: • are age 35 years of age or older • have a previous child having chromosome abnormality or multiple congenital abnormalities • have had two or more previous spontaneous abortions • have a family history of a chromosome abnormality • are known carriers of an X-linked disorder • are 31 years of age or older with twin pregnancies • have abnormal fetal ultrasound findings • have a positive maternal serum marker screen Additional biochemical or molecular tests may be performed on the cultured amniocytes.

Methodology

In situ cell culturing of amniocytes to investigate numerical and/or structural chromosome abnormalities

Collection instructions

Discard first 2 mL of fluid aspirated to avoid maternal cell contamination. Specimen is collected in a 20 mL sterile syringe and transferred aseptically to sterile tubes to be transported to Labcorp. Request form is completed and accompanies specimen and miscellaneous slip to the laboratory. Samples from twin (multiple) pregnancies should be appropriately labeled and placed in separate transport containers with a separate request form for each twin. Rubber stopper and/or frozen specimen cannot be processed.

Patient preparation

The patient preferably should have had ultrasound studies (to verify fetal life, detect multiple gestation, confirm gestational age, localize fetus/placenta).

Causes for rejection

Upon receipt, suitability of specimen will be determined by the Cytogenetics laboratory.

Special instructions

If prior NIPT studies have been performed, include copy of the report.

Limitations

Although the overall culture success rate is reported as >99%, culture failure can result. Reasons include (but are not limited to) lack of amniocytes in the fluid and contamination of the fluid with bacteria or yeast. This test was developed and its performance characteristics determined by Labcorp. It has not been cleared or approved by the Food and Drug Administration.

LOINC map

Result codeResult nameUnitsResult LOINC
052138Cells Counted64095-3
052139Colonies64096-1
052140Cells Analyzed64092-0
052141Cells Karyotyped64091-2
052143GTG Band Resolution Achieved64093-8

View this test on Labcorp's website → · Last checked 2026-11-29

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation