Labcorp test 017100, CPT 84163. Specimen: Serum. Turnaround: 2 - 5 days.

Integrated 1 is Labcorp test code 017100, billed with CPT 84163. Specimen: Serum. Turnaround time: 2 - 5 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Cleveland Clinic Laboratories, Michigan Medicine Laboratories (MLabs).
LaboratoryLabcorp
CLIA number34D0655059
Test code017100 (Women's Health)
CPT84163
LOINC11957-8, 49586-1
SpecimenSerum
Volume3 mL
Minimum volume1 mL
ContainerGel-barrier tube
Turnaround time2 - 5 days
Storage / transportRoom temperature

Also known as: Down Syndrome; Nuchal Translucency (NT); PAPP-A

Use

This is a screening test for open neural tube defects, Down syndrome and trisomy 18.

Methodology

Chemiluminescent immunoassay

Collection instructions

Collect in serum separator tube with gel barrier. Allow blood to clot, avoiding hemolysis. Separate serum from cells by centrifugation. Transport spun tube to testing laboratory. Pour-off is not advised. Maternal serum specimens must be drawn prior to amniocentesis to avoid contamination with fetal blood.

Stability

TemperaturePeriod
Room temperature7 days
Refrigerated14 days
Frozen14 days
Freeze/thaw cyclesStable x3

Causes for rejection

Gross hemolysis; gross lipemia; quantity not sufficient for analysis; improper specimen type

Special instructions

For test inquiries, call CMBP genetic services at 800-345-4363. Client must provide fetal nuchal translucency (NT) measurement and crown rump length measurement. The NT measurement must be performed by a sonographer credentialed by the Fetal Medicine Foundation or other equivalent entity. The sonographer's credential/certification number must be provided. The following information also must be provided: patient's race, patient's weight, patient's date of birth, patient's insulin-dependent diabetic status, and the number of fetuses. Also indicate patient history (i.e. prior Down syndrome pregnancy, ultrasound anomalies). Complete information is necessary to interpret the test. Patient information may be provided to the laboratory using the Maternal Prenatal Screening requisition 0900. Serum testing is provided from 10.0 to 14.0 weeks of gestation. NT can be assessed when the CRL is 45 to 84 mm.

Limitations

Integrated screening requires two specimens: one collected in the first trimester and one in the second trimester. This test number is for the first trimester portion of the test. Result interpretation will be provided only when the second trimester specimen is received and tested. This is a screening test. A positive result means that diagnostic testing may be offered to the pregnant woman to determine if a neural tube defect or chromosome abnormality is present. This test was developed and its performance characteristics determined by Labcorp. It has not been cleared or approved by the Food and Drug Administration.

LOINC map

Result codeResult nameUnitsResult LOINC
Integrated 1017101Test Results:49586-1
017103Crown Rump Lengthmm11957-8
Crown Rump Length Twin Bmm11957-8

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 84163

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation