Hepatitis B Core Antibody, IgM (Women's Health): Labcorp test 016881

Labcorp test 016881, CPT 86705. Specimen: Serum. Turnaround: 1 - 2 days.

Hepatitis B Core Antibody, IgM is Labcorp test code 016881, billed with CPT 86705. Specimen: Serum. Turnaround time: 1 - 2 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, Michigan Medicine Laboratories (MLabs), ARUP Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code016881 (Women's Health)
CPT86705
LOINC24113-3
SpecimenSerum
Volume1 mL
Minimum volume0.4 mL ( Note: This volume does not allow for repeat testing.)
ContainerGel-barrier tube, red-top tube or serum transfer tube
Turnaround time1 - 2 days
Storage / transportRoom temperature

Also known as: Anti-HBc, IgM; Antibody to Hepatitis B Core Antigen, IgM; HBV

Use

This assay may be used in combination with other hepatitis B virus (HBV) marker assays to define the clinical status of known HBV infected patients or can be combined with other HBV, HAV (hepatitis A virus), and HCV (hepatitis C virus) assays for the diagnosis of patients presenting with symptoms of acute viral hepatitis.

Methodology

Immunochemiluminometric assay (ICMA)

Collection instructions

If tube other than a gel-barrier tube is used, transfer separated serum to a screw-cap polypropylene transport tube. Do not freeze gel-barrier tube (pour off serum first).

Stability

TemperaturePeriod
Room temperature14 days
Refrigerated14 days
Frozen14 days
Freeze/thaw cyclesStable x3

Causes for rejection

Gross hemolysis, obvious microbial contamination, and/or received outside of specimen and/or storage and/or labeling requirements; heat-inactivated samples; cadaveric samples

Reference range

Negative

Special instructions

This test may exhibit interference when sample is collected from a person who is consuming a supplement with a high dose of biotin (also termed as vitamin B7 or B8, vitamin H, or coenzyme R). It is recommended to ask all patients who may be indicated for this test about biotin supplementation. Patients should be cautioned to stop biotin consumption at least 72 hours prior to the collection of a sample.

Limitations

Assay performance characteristics have not been established for immunocompromised or immunosuppressed patients, cord blood, or patients less than 2 years of age. Heterophilic antibodies in human serum can react with reagent immunoglobulins, interfering with in vitro immunoassays. Patients routinely exposed to animals or to animal serum products can be prone to this interfence and anomalous values may be observed. Additional information may be required for diagnosis. A reactive anti-HBc IgM result does not exclude co-infection by another hepatitis virus. Assay performance characteristics have not been established when the ADVIA Centaur HBc IgM assay is used in conjunction with other…

LOINC map

Result codeResult nameUnitsResult LOINC
016881Hep B Core Ab, IgM24113-3

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 86705

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation