Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Myoglobin

Myoglobin: Labcorp test 010405

Labcorp test 010405, CPT 83874. Specimen: Serum. Turnaround: 1 - 3 days.

Myoglobin is Labcorp test code 010405, billed with CPT 83874. Specimen: Serum. Turnaround time: 1 - 3 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, ARUP Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code010405
CPT83874
LOINC2639-3
SpecimenSerum
Volume1 mL
Minimum volume0.7 mL ( Note: This volume does not allow for repeat testing.)
ContainerGel-barrier tube (preferred) or red-top tube
Turnaround time1 - 3 days
Storage / transportRoom temperature

Use

Diagnose skeletal or myocardial muscle injury. Serum myoglobin is generally detectable earlier than is CK or CK-MB increase in patients with acute myocardial infarction. Serum myoglobin was found also in 50% of patients with acute coronary insufficiency. It is thought to define a population of small infarcts of myocardium. It correlates with size of infarct. Diagnose rhabdomyolysis. Myoglobin appears with trauma, ischemia, malignant hyperthermia, exertion, dermatomyositis, polymyositis, and muscular dystrophy.

Methodology

Electrochemiluminescence immunoassay (ECLIA)

Collection instructions

If a red-top tube is used, transfer separated serum to a plastic transport tube.

Stability

TemperaturePeriod
Room temperature14 days
Refrigerated14 days
Frozen14 days
Freeze/thaw cyclesStable x3

Causes for rejection

Gross hemolysis

Reference range

• Male 28−72 ng/mL • Female 25−58 ng/mL

Special instructions

This test may exhibit interference when sample is collected from a person who is consuming a supplement with a high dose of biotin (also termed as vitamin B7 or B8, vitamin H, or coenzyme R). It is recommended to ask all patients who may be indicated for this test about biotin supplementation. Patients should be cautioned to stop biotin consumption at least 72 hours prior to the collection of a sample.

Limitations

Lacks specificity in diagnosis of acute MI, since increased myoglobin levels occur after intramuscular injections. Increased serum myoglobin has been reported after a high voltage electrical accident. As an index of myocardial infarct, myoglobin returns rapidly to baseline levels.

LOINC map

Result codeResult nameUnitsResult LOINC
010405Myoglobin, Serumng/mL2639-3

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 83874

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation