Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Miscellaneous Fluid Cytology

Miscellaneous Fluid Cytology: Labcorp test 009159

Labcorp test 009159, CPT 88112. Specimen: Fluid. Turnaround: 2 - 6 days.

Miscellaneous Fluid Cytology is Labcorp test code 009159, billed with CPT 88112. Specimen: Fluid. Turnaround time: 2 - 6 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Cleveland Clinic Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code009159
CPT88112
LOINC22633-2, 32785-8, 47526-9, 52797-8
SpecimenFluid
Volume1 to 2 mL
Minimum volume1 mL
ContainerSterile container; nongynecologic liquid-based cytology vial
Turnaround time2 - 6 days
Storage / transportRefrigerate immediately after collection and ship to laboratory as soon as possible.

Also known as: Anal Specimens; Colon Wash Cytology; Cyst Fluid Cytology; Endometrial Aspiration Samples; Gastric Washing Cytology; HALO™ Ocular Cytology; Joint/Synovial Fluid Cytology; Nipple Fluid Aspiration; Ovarian Fluid Cytology; Spinal Fluid Cytology

Test includes

Routine cytologic evaluation of smears, monolayers, filters, and cell block when indicated

Use

Diagnose primary and metastatic malignant neoplasms; differential diagnosis of benign versus malignant processes

Methodology

The fluid will be centrifuged, supernatant poured off, and diagnostic cells aspirated from the remaining material. Filters, monolayers, and/or cytospins will be made along with a cell block, if applicable. Microscopic examination is performed.

Collection instructions

Mix entire specimen with an equal volume of 50% ethyl alcohol or Saccomanno fixative. ( Note: Specimens prepared with fixatives that contain 50% ethyl alcohol, eg, Saccomanno fixative, are not acceptable for microbiology testing.) Specify source of specimen.

Causes for rejection

Improper labeling; improper fixation; specimen submitted in vial that expired according to manufacturer's label; frozen specimen

Special instructions

Include patient's name, date of birth, Social Security number, source, previous malignancy, drug therapy, radiation therapy, and all other pertinent clinical information on the request form.

LOINC map

Result codeResult nameUnitsResult LOINC
191115Specimen type:22633-2
191152Source:22633-2
191160Clinician provided ICD9:52797-8
191174Clinician provided ICD10:52797-8
191118DIAGNOSIS:47526-9

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 88112

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation