Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Breast Discharge Cytology

Breast Discharge Cytology: Labcorp test 009134

Labcorp test 009134, CPT 88160. Specimen: Nipple discharge. Turnaround: Within 1 day.

Breast Discharge Cytology is Labcorp test code 009134, billed with CPT 88160. Specimen: Nipple discharge. Turnaround time: Within 1 day. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Michigan Medicine Laboratories (MLabs), Cleveland Clinic Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code009134
CPT88160
LOINC22633-2, 52797-8
SpecimenNipple discharge
VolumePea-size drop
ContainerCardboard or plastic slide holder(s), Coplin jar(s)
Turnaround timeWithin 1 day
Storage / transportMaintain specimen at room temperature.

Also known as: Breast Smear; Nipple Discharge

Use

This test is used to diagnose primary or metastatic malignant neoplasms; for differential diagnosis of benign versus malignant processes; and to aid in the diagnosis of infectious and inflammatory disease.

Methodology

Pap stained: microscopic examination

Collection instructions

Gently grip subareolar area and nipple with thumb and forefinger. When secretion occurs, allow pea-sized drop to accumulate on apex of nipple. Touch a clean slide to the nipple and withdraw quickly. Immediately spray slide with fixative or place slides in 95% ethyl alcohol. Repeat procedure until all secretions from nipple are collected on two or more slides. Using a graphite pencil, label the frosted end of the slide with the patient's name.

Causes for rejection

Improper labeling; improper fixative; air-drying artifact

Special instructions

Include patient's name, date of birth, sex, Social Security number, previous malignancy, drug therapy, radiation therapy, mammogram, and all other pertinent clinical information on the request form.

Limitations

Drying of smear(s) before fixation will render specimen unsatisfactory for evaluation.

LOINC map

Result codeResult nameUnitsResult LOINC
Breast Discharge Cytology191152Source:22633-2
Breast Discharge Cytology191174Clinician provided ICD10:52797-8

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 88160

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation