Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Gynecologic Pap Smear, One Slide, Two Slides

Gynecologic Pap Smear, One Slide, Two Slides: Labcorp test 009100 (one slide); 009191 (two slides)

Labcorp test 009100 (one slide); 009191 (two slides), CPT 88164. Specimen: Endocervical brush and cervical scrape are recommended in all cases. Aspiration of posterior vaginal fornix (vaginal poo. Turnaround: 2 - 5 days.

Gynecologic Pap Smear, One Slide, Two Slides is Labcorp test code 009100 (one slide); 009191 (two slides), billed with CPT 88164. Specimen: Endocervical brush and cervical scrape are recommended in all cases. Aspiration of posterior vaginal fornix (vaginal pool) may also be used . Turnaround time: 2 - 5 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Michigan Medicine Laboratories (MLabs).
LaboratoryLabcorp
CLIA number34D0655059
Test code009100 (one slide); 009191 (two slides)
CPT88164 (each test)
LOINC—
SpecimenEndocervical brush and cervical scrape are recommended in all cases. Aspiration of posterior vaginal fornix (vaginal pool) may also be used but is not a substitute for cervical specimens. Endometrial aspirations are not advised for routine use. For lesions of the vagina or vulva, scrapings made directly from lesion are desirable. Scraping of upper one-third of lateral vaginal wall is most suitable for hormonal evaluation.
ContainerSlides and other supplies, including cytospray fixative, slide holders, and request forms are available from courier service. Commercial Pap collection kits are also available.
Turnaround time2 - 5 days
Storage / transportMaintain specimen at room temperature. Slides may be stored indefinitely when spray fixed.

Also known as: Cervical/Vaginal Smear; Genital Cytology; Papanicolaou Smear; Vaginal Cytology

Use

Diagnose primary or metastatic neoplasms; diagnose genital infections with herpesvirus, Candida , Trichomonas vaginalis , cytomegalovirus, Actinomyces , cervicovaginal endometriosis, human papillomavirus (HPV), and lymphogranuloma venereum; aid in evaluating hormonal function (maturation index) in vaginal specimens

Methodology

Pap stained: microscopic examination

Collection instructions

Preferred fixative: Cytospray fixative or 95% ethyl alcohol. Patient identification of specimen: Each Vaginal Cervical Endocervical (VCE) slide must be labeled with patient name and origin of site, written with graphite pencil on frosted end of slide. Nonfrosted end should be labeled with diamond point pen. Sampling − Endocervix: Cervical aspiration or brush of endocervical canal • Endocervical smear is prepared by inserting endocervical brush into endocervical canal and rotating the brush. Spread material onto labeled glass slide and fix immediately with spray fixative. • Ectocervical scrape: With spatula, thoroughly scrape the entire ectocervix with emphasis on the squamocolumnar junction. Spread material evenly onto labeled glass slide and fix immediately. • Vaginal smear: If vaginal smear is desired, obtain specimen by lightly scraping the posterior fornix with spatula. Spread material evenly onto labeled glass slide and fix immediately. (Make cell spread from the vaginal pool first: fix slide immediately, then make cell spread from the cervix and fix the slide immediately before collecting the endocervical specimens.) • Vaginal smear for hormonal evaluation, obtain cells from the upper third of the lateral vaginal wall. Spread material evenly onto labeled glass slide and fix immediately. Fixation: If more than one slide is immersed in fixation solution, attach a paper clip to each slide to separate slides and allow adequate fixation. Spray fixation with cytospray fixative is preferred. Processing: Place slides in cardboard holders or fixative jars and include completed test request form and secure.

Patient preparation

Patient should avoid douches 48 to 72 hours prior to examination. Specimen should not be collected during or shortly after menstrual period. Excessive use of lubricating jelly will interfere with cytologic examination.

Causes for rejection

Improper labeling; fixation in formalin; air-drying artifact

Special instructions

Include patient's name, date of birth, Social Security number (or other identification number), previous malignancy, drug therapy, radiation therapy, last menstrual period (LMP), postmenopausal patient (PMP), surgery (including surgical biopsies), exogenous hormones, abnormal vaginal bleeding, abnormal Pap results, IUD, and all other pertinent clinical information on the test request form. Note: In accordance with criteria established by CLIA, Pap tests will be referred for pathologist review if laboratory personnel suspect: • Reactive or reparative cellular changes • Atypical squamous or glandular cells of undetermined significance • Cells in the premalignant or malignant category In these cases, LabCorp will charge for the associated service. (Slides that are routinely reviewed by a pathologist for quality control purposes are not included.)

Limitations

Failure to obtain adequate ectocervical, endocervical, or vaginal cell population is suboptimal for evaluation. Excessive use of lubricating jelly on the vaginal speculum will interfere with cytologic examination and may lead to unsatisfactory Pap results. All powder should be wiped off gloves before spatulas are handled since presence of starch granules will make interpretation of slides difficult. Inflammatory reaction may preclude hormonal evaluation. A very significant proportion of adenocarcinomas of endometrium are not detected by this means. Occasionally, highly differentiated adenocarcinomas of endocervix can be missed. Occasional aggressive lesions of squamous epithelium of cervix…

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 88164

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation