Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Urine Culture, Routine

Urine Culture, Routine: Labcorp test 008847

Labcorp test 008847, CPT 87086. Specimen: Urine. Turnaround: 2 - 4 days.

Urine Culture, Routine is Labcorp test code 008847, billed with CPT 87086. Specimen: Urine. Turnaround time: 2 - 4 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Michigan Medicine Laboratories (MLabs), ARUP Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code008847
CPT87086
LOINC630-4
SpecimenUrine
VolumeTo minimum fill line (4 mL) on Vacutainer® gray-top urine culture transport tube with preservative (preferred)
ContainerVacutainer® gray-top urine culture transport tube with preservative (preferred). If less than 4 mL of urine is collected, usually from pediatric and geriatric patients or from a catheter, submit refrigerated in a sterile, screw cap container or tube. Do not submit low volume urine specimens in underfilled gray top tubes.
Turnaround time2 - 4 days
Storage / transportPreserved: Room temperature for 48 hours Unpreserved: Refrigerated for 24 hours

Also known as: Culture, Urine, Routine; Midstream Urine Culture, Routine; Routine Culture, Urine, Clean Catch; Urine Culture, Catheter; Urine Culture, Routine, Midvoid Specimen

Test includes

Culture; quantitation, isolation, identification (additional charges/CPT code[s] may apply), and susceptibility testing of up to two organisms at >10,000 colonies/mL if culture results warrant (additional charges/CPT code[s] may apply). CPT coding for microbiology and virology procedures often cannot be determined before the culture is performed. Requests with only a written order and no test number indicated will be processed according to Default Testing for Routine Microbiology .

Use

Semiquantitative culture to isolate and identify bacterial causes of urinary tract infection. Detect up to two pathogenic bacterial organisms at levels above 10,000 cfu/mL.

Methodology

Culture

Collection instructions

Clean catch mid-stream collection. First morning specimens yield highest bacterial counts from overnight incubation in the bladder, and are the best specimens. Read Patient Preparation.

Patient preparation

Patient should be instructed on the proper collection of a clean catch midstream urine specimen. Avoid contamination with normal flora from skin, rectum or vagina. If a clean catch urine cannot be obtained from an infant, obtain a bagged specimen: clean area as for a clean catch, attach U-bag, and put collected urine into a sterile container. Clean catch specimen: Have patient urinate into a small clean disposable cup (styrofoam or “Dixie”). Afterward, collection site staff can transfer the urine to the urine culture transport tube using the special collection straw-puncture device designed for use with the Vacutainer® tubes. The numbers of bacteria in a clean unused cup are so few as to be inconsequential when the urine transport stabilizer is added. Thoroughly instruct patient for proper collection of a “clean catch” specimen. Patient must be instructed to thoroughly cleanse skin and collect a midstream specimen. The patient should be instructed to follow the directions provided with the urine collection kit as follows. Catheterized specimen: Refers to an “in and out” catheter that is placed into the bladder solely for collection of the specimen and then withdrawn. Do not collect urine from the drainage bag when an indwelling catheter is in place because growth of bacteria can occur in the bag itself. Rather, clean catheter with an alcohol sponge, puncture with a sterile needle, and collect in sterile syringe. Catheter tips are contaminated by the urethra as they are withdrawn; do not culture them. Male: Wash hands thoroughly with soap and water. Rinse them well and dry with a paper towel. • Tear open the towelette packages so that the towels can be easily removed with one hand as they are needed. Do not touch any of the inside surfaces of the collection cup. • Pull back the foreskin to expose the head of the penis completely. • Wash the head of the penis thoroughly using first one towelette then the other. Discard the used towelettes into the toilet bowl. • Pass a small amount of urine into the toilet bowl, then pass a sample into the container. Do not allow the container to touch the legs or penis. Keep fingers away from the rim and inner surface of the container. Fill the container half full. • The urine specimen should be transferred to the Vacutainer® tube within 10 minutes of collection. Female: Wash hands thoroughly with soap and water. Rinse them well and dry with a paper towel. • Tear open the towelette packages so that the towels can be easily removed with one hand as they are needed. Do not touch any of the inside surfaces of the collection cup. • Remove undergarments and sit on the toilet seat with legs spread widely apart. • With one hand, spread labia apart to expose the vulva. Keep this hand in place during the washing and urinating procedure. • Use one towelette to wash the vulva well passing the towelette only from front to back, not back and forth. Repeat this procedure using the second towelette. Discard the used towelettes i

Causes for rejection

Unrefrigerated, unpreserved specimen greater than two hours old; unlabeled specimen or name discrepancy between specimen and request label; specimen in expired transport container; specimen received after prolonged delay (usually more than 48 hours for urine); specimen collected from a Foley catheter bag; specimen in nonsterile or leaking container

Special instructions

Unrefrigerated, unpreserved urine specimens greater than two hours old may be subject to overgrowth with organisms normally present in the urethra and periurethral areas, and may yield inaccurate or misleading results. If specimens are incorrectly submitted with an order for aerobic bacterial culture, the laboratory will process the specimen for the test based on the source listed on the request form. The client will not be contacted to approve this change, but the change will be indicated on the report.

LOINC map

Result codeResult nameUnitsResult LOINC
008847Urine Culture, Routine630-4

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 87086

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation