Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Lead, Whole Blood (Adult)

Lead, Whole Blood (Adult): Labcorp test 007625

Labcorp test 007625, CPT 83655. Specimen: Whole blood. Turnaround: 2 - 4 days.

Lead, Whole Blood (Adult) is Labcorp test code 007625, billed with CPT 83655. Specimen: Whole blood. Turnaround time: 2 - 4 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Michigan Medicine Laboratories (MLabs), Cleveland Clinic Laboratories, ARUP Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code007625
CPT83655
LOINC77307-7
SpecimenWhole blood
Volume1 mL
Minimum volume0.5 mL
ContainerRoyal blue-top (EDTA) tube or tan-top lead-free tube; submit original tube Royal blue-top (EDTA) tube or tan-top lead-free tube; submit original tube. Royal blue-top (EDTA) tube or tan-top lead-free tube; submit original tube
Turnaround time2 - 4 days
Storage / transportMaintain specimen at room temperature.

Use

This test is used to monitor exposure to lead. Monitor exposure to lead This test is used to monitor exposure to lead.

Methodology

Atomic absorption spectrometry (AAS) or inductively coupled plasma/mass spectrometry (ICP/MS)

Collection instructions

Sampling time is not critical for industrial exposure monitoring. Metals with timing “not critical” have very long elimination half-lives and accumulate in the body over years, some for a lifetime. After a couple of weeks of exposure, specimens can be collected at any time.

Stability

TemperaturePeriod
Room temperature28 days
Refrigerated28 days
Frozen28 days
Freeze/thaw cyclesStable x4
TemperaturePeriod
Room temperature14 days
Refrigerated14 days
Frozen14 days
Freeze/thaw cyclesStable x3
TemperaturePeriod
Room temperature28 days
Refrigerated28 days
Frozen28 days
Freeze/thaw cyclesStable x4

Causes for rejection

Clotted specimen

Reference range

0.0–3. 4 μg/dL • Environmental exposure (WHO): <20 μg/dL • Occupational exposure: BEI® (sampling time is not critical): 30 μg/dL; OSHA Lead Standard: 40 μg/dL 0.0 -3. 4 μg/dL • Environmental exposure (WHO): <20 μg/dL • Occupational exposure: BEI® (sampling time is not critical): 30 μg/dL; OSHA Lead Standard: 40 μg/dL 0.0 –3. 4 μg/dL • Environmental exposure (WHO): <20 μg/dL • Occupational exposure: BEI® (sampling time is not critical): 30 μg/dL; OSHA Lead Standard: 40 μg/dL

Limitations

This test was developed and its performance characteristics determined by Labcorp. It has not been cleared or approved by the Food and Drug Administration.

LOINC map

Result codeResult nameUnitsResult LOINC
007631Lead, Blood (Adult)ug/dL77307-7

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 83655

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation