Labcorp test 007419, CPT 80156. Specimen: Serum or plasma. Turnaround: Within 1 day.

Carbamazepine, Serum or Plasma is Labcorp test code 007419, billed with CPT 80156. Specimen: Serum or plasma. Turnaround time: Within 1 day. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, Michigan Medicine Laboratories (MLabs), ARUP Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code007419
CPT80156
LOINC3432-2
SpecimenSerum or plasma
Volume1 mL
Minimum volume0.3 mL
ContainerRed-top tube or green-top (heparin) tube. Do not use a gel-barrier tube. The use of gel-barrier tubes is not recommended due to slow absorption of the drug by the gel. Depending on the specimen volume and storage time, the decrease in drug level due to absorption may be clinically significant.
Turnaround timeWithin 1 day
Storage / transportRoom temperature

Also known as: Carbatrol®; Epitol®; Equetro®; Tegretol®

Use

This heterocyclic (iminostilbene) compound has potent antiepileptic properties and is effective alone or with other antiepileptic drugs in partial seizures, especially complex partial seizures, generalized tonic-clonic seizures, and combinations of these seizure types. Carbamazepine generally is ineffective for absence, myoclonic, and atonic seizures. In children with symptomatic generalized epilepsy and continuous spike-and-wave discharge, these seizure types may develop or tonic-clonic seizures may increase in frequency with use of carbamazepine. It has also been noted that the dose of carbamazepine cannot be used as a reliable index for predicting the serum concentration of either total…

Methodology

Immunoassay

Collection instructions

Transfer separated serum or plasma to a plastic transport tube. Draw trough levels immediately prior to next dose. Due to variability of absorption, the trough level may not represent the lowest drug level during the dosing interval, so multiple determinations may be necessary in some patients.

Stability

TemperaturePeriod
Room temperature14 days
Refrigerated14 days
Frozen14 days
Freeze/thaw cyclesStable x3

Causes for rejection

Gel-barrier tube; hemolysis; gross lipemia; icteric specimen

Reference range

Therapeutic : In conjunction with other antiepileptic drugs: 4.0−8.0 μg/mL; carbamazepine alone: 6.0−12.0 μg/mL

LOINC map

Result codeResult nameUnitsResult LOINC
007422Carbamazepine(Tegretol), Sug/mL3432-2

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 80156

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation