Labcorp test 007187, CPT 82375. Specimen: Whole blood. Turnaround: 2 - 5 days.

Carbon Monoxide, Whole Blood is Labcorp test code 007187, billed with CPT 82375. Specimen: Whole blood. Turnaround time: 2 - 5 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, ARUP Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code007187
CPT82375
LOINC20563-3
SpecimenWhole blood
Volume7 mL
Minimum volume0.6 mL
ContainerLavender-top (EDTA) tube or green-top (heparin) tube; submit original full, unopened tube.
Turnaround time2 - 5 days
Storage / transportRefrigerate immediately after collection. Do not remove cap.

Also known as: Carboxyhemoglobin, Blood

Test includes

Carboxyhemoglobin, blood

Use

Determine the extent of carbon monoxide poisoning, toxicity; check on the effect of smoking on the patient; work up headache, irritability, nausea, vomiting, vertigo, dyspnea, collapse, coma, convulsions; work up persons exposed to fires and smoke inhalation

Methodology

Co-oximetry

Collection instructions

Sampling time is end of shift for industrial exposure monitoring. Analytes with timing “end of shift” (meaning the last two hours of exposure) are eliminated rapidly with a half-life less than five hours. Such compounds do not accumulate in the body and, therefore, their timing is critical only in relation to the exposure period.

Stability

TemperaturePeriod
Refrigerated28 days

Patient preparation

A morning specimen is not as good as one that is drawn in the late afternoon or evening, especially if the patient is an outpatient who may have occupational exposure (ie, policemen, firemen on day shifts, mechanics). CO tends to be cleared from the blood in hours. Treatment for carbon monoxide poisoning involves removal of the individual from the contaminated area and the administration of oxygen. The half-life of carboxyhemoglobin is five to six hours when the patient breathes room air; it is reduced to 1 to 1/ 2 hours when the patient breathes 100% oxygen. In severe cases, hyperbaric oxygen treatment at two to three atmospheres is recommended, if available. In the latter instance, the carboxyhemoglobin half-life is reduced to approximately 25 minutes. Hyperbaric oxygen therapy may reduce the incidence of neurological manifestations after exposure. Hyperbaric oxygen therapy has been recommended when the carboxyhemoglobin concentration exceeds 25%. Some have cautioned against basing decisions to institute hyperbaric oxygenation solely on the carboxyhemoglobin concentration owing to the inconsistent correlation between such a measurement and clinical severity.

Causes for rejection

Clotted specimen

Reference range

• Environmental exposure: Nonsmoker: <2.0%, smoker: <9.0% • Occupational exposure: BEI®: 3.5%

Limitations

Carbon monoxide levels are of limited value in testing for smoking, since it is cleared rapidly. The half-life of carboxyhemoglobin in individuals with normal cardiopulmonary function is one to two hours. Urinary cotinine, if available, is preferable as a test for tobacco use. Arterial blood gases may be of limited value in treatment decisions for carbon monoxide poisoning.

LOINC map

Result codeResult nameUnitsResult LOINC
007189Carbon Monoxide, Blood%20563-3

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 82375

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation