Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Hemoglobin (Hb), Free, Plasma

Hemoglobin (Hb), Free, Plasma: Labcorp test 005595

Labcorp test 005595, CPT 83051. Specimen: Plasma. Turnaround: 3 - 4 days.

Hemoglobin (Hb), Free, Plasma is Labcorp test code 005595, billed with CPT 83051. Specimen: Plasma. Turnaround time: 3 - 4 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, ARUP Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code005595
CPT83051
LOINC721-1
SpecimenPlasma
Volume1 mL
Minimum volume0.1 mL ( Note: This volume does not allow for repeat testing.)
ContainerGreen-top (heparin) tube
Turnaround time3 - 4 days
Storage / transportRefrigerate at 2°C to 8°C or freeze at -20°C for up to six days.

Also known as: Free Hemoglobin; Hb Solubility; Hemoglobin, Free; Plasma Free Hemoglobin

Use

Evaluate hemolytic anemia, especially intravascular hemolysis. Plasma hemoglobin is increased with intravascular hemolysis, ABO incompatible transfusion, traumatic hemolysis, falciparum malaria, burns, and march hemoglobinuria. Increase may occur in some cases of extravascular hemolysis, delayed transfusion reaction, slight increase in sickle cell anemia, and β-thalassemia.

Methodology

Based on the catalytic action of hemoglobin on the oxidation of TMB by hydrogen peroxide; rate measured by spectrophotometry

Collection instructions

Recommended procedure for collecting sample without inducing hemolysis: An 18-gauge needle with attached infusion tubing is used. Place the tourniquet lightly around the upper arm. Puncture an antecubital vein with as little trauma as possible. Release the tourniquet and clamp the tubing off as soon as blood return is seen. First collect 3 mL blood in a red-top tube with the rubber top off. Then, collect 5 mL in an anticoagulated tube with the top off. Clamp the tubing, withdraw the needle, and apply a pressure bandage to the site until residual bleeding is stopped. Recap the anticoagulant tube and gently mix three to five times. This specimen is used for the plasma hemoglobin determination. Centrifuge and separate plasma from red cells immediately following collection and transfer plasma to a transfer tube.

Stability

TemperaturePeriod
Room temperature6 days
Refrigerated6 days
Frozen6 days
Freeze/thaw cyclesStable x3

Patient preparation

Patient should not exercise just prior to the test.

Causes for rejection

Traumatic venipuncture causing hemolysis; very icteric or lipemic specimen; specimen not heparinized plasma

Reference range

<5 mg/dL (if conditions are optimal). Values obtained between 5−15 mg/dL should be interpreted with caution since such variables as suboptimal venipuncture may increase results to this range.

Limitations

High (>20 mg/dL) bilirubin, turbidity, methemalbuminemia, lipemic plasma, and hemolysis during or after venipuncture may cause falsely elevated values in the plasma hemoglobin test (method based on peroxide oxidation of TMB). Results of this test are labeled for research purposes only by the assay's manufacturer. The performance characteristics of this assay have not been established by the manufacturer. The result should not be used for treatment or for diagnostic purposes without confirmation of the diagnosis by another medically established diagnostic product or procedure. The performance characteristics were determined by LabCorp.

LOINC map

Result codeResult nameUnitsResult LOINC
005596Hemoglobin, Free, Plasmamg/dL721-1

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 83051

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation