Sound Lab Consultants › National Lab Test Directory › Labcorp › Eosinophil Count

Eosinophil Count: Labcorp test 005298

Labcorp test 005298, CPT 85048. Specimen: Whole blood. Turnaround: Within 1 day.

Eosinophil Count is Labcorp test code 005298, billed with CPT 85048. Specimen: Whole blood. Turnaround time: Within 1 day. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, Quest Diagnostics.
LaboratoryLabcorp
CLIA number34D0655059
Test code005298
CPT85048
LOINC711-2
SpecimenWhole blood
VolumeTube fill capacity
Minimum volume0.5 mL (500 μL for Pediatric Microtainer capillary tubes; fill tube to capacity) ( Note: This volume does not allow for repeat testing.)
ContainerLavender-top (EDTA) tube
Turnaround timeWithin 1 day
Storage / transportMaintain specimen at room temperature.

Also known as: Absolute Eosinophil Count; Total Eosinophil Count

Test includes

Enumeration of eosinophils with a cell counter

Use

Usually increased in allergy, parasitic infestations, tuberculosis, brucellosis, collagen disease, Hodgkin disease, myeloproliferative diseases, and the acute hypereosinophilic syndrome; increased also in angioneurotic edema, dermatitis, thymic disorders, radiotherapy, splenectomy, convalescence from a febrile illness, and hypoadrenocorticism (Addison disease). Decreased eosinophils occurs in adrenal cortical hyperplasia (Cushing syndrome), cortisone therapy, hormone-secreting tumors, intermenstrual period, acute and chronic inflammation, and anoxia.

Methodology

Automated cell counter

Collection instructions

Invert tube 8 to 10 times immediately after tube is filled at the time of collection.

Stability

TemperaturePeriod
Room temperature1 day
Refrigerated3 days
FrozenUnstable
Freeze/thaw cyclesUnstable

Causes for rejection

Hemolysis; clotted specimen; quantity not sufficient for analysis; specimen diluted or contaminated with IV fluid; anticoagulant other than EDTA; specimen received with plasma removed; improper labeling; transport tube with whole blood

LOINC map

Result codeResult nameUnitsResult LOINC
015933Eos (Absolute)x10E3/uL711-2

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 85048

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation