Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › DHEA-Sulfate by Ionify LC-MS/MS

DHEA-Sulfate by Ionify LC-MS/MS: Labcorp test 005165

Labcorp test 005165, CPT 82627. Specimen: Serum (preferred) or plasma. Turnaround: 3 - 5 days.

DHEA-Sulfate by Ionify LC-MS/MS is Labcorp test code 005165, billed with CPT 82627. Specimen: Serum (preferred) or plasma. Turnaround time: 3 - 5 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Cleveland Clinic Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code005165
CPT82627 To be determined. Updates will be made when available. 82627 Share Print Updated on 10/19/2026 View Changes Test Details Specimen Requirements Test Details Methodology Ionify LC-MS/MS Result Turnaround Time 3 - 5 days Turnaround time is defined as the usual number of days from the date of pickup of a specimen for testing to when the result is released to the ordering provider. In some cases, additional time should be allowed for additional confirmatory or additional reflex tests. Testing schedules may vary. Use This test is used to identify the source of excessive androgen; it aids in the evaluation of androgen excess (hirsutism and/or virilization), including Stein-Leventhal syndrome and adrenocortical diseases, including congenital adrenal hyperplasia and adrenal tumor. DHEA-S is not increased with hypopituitarism; it is low in Addison disease. This test is used to identif i y the source of excessive androgen; it aids in the evaluation of androgen excess (hirsutism and/or virilization), including Stein-Leventhal syndrome and adrenocortical diseases, including congenital adrenal hyperplasia and adrenal tumor. DHEA-S is not increased with hypopituitarism; it is low in Addison disease. This test is used to identif y the source of excessive androgen; it aids in the evaluation of androgen excess (hirsutism and/or virilization), including Stein-Leventhal syndrome and adrenocortical diseases, including congenital adrenal hyperplasia and adrenal tumor. DHEA-S is not increased with hypopituitarism; it is low in Addison disease. Custom Additional Information DHEA-S is a steroid hormone synthesized in the zona reticularis of the adrenal glands in response to adrenocorticotropic hormone (ACTH). Like other steroids, DHEA-S is synthesized from cholesterol. DHEA-S is hormonally inert, but it can be converted to other more potent androgens or estrogens. Therefore, DHEA-S can be considered a prohormone. During fetal development, DHEA-S is produced in the adrenal gland and the level declines rapidly during the first year of life. The production of DHEA-S resumes again during adrenarche, increases during puberty, and reaches the peak values between 20 and 30 years of age. Thereafter, DHEA-S levels steadily decline. The determination of elevated DHEA-S values is an important aid in the diagnosis of hyperandrogenism states, such as polycystic ovarian syndrome (PCOS) and congenital adrenal hyperplasia. In addition, further indications for this parameter are other forms of androgenization, such as premature adrenarche, hyperprolactinemia and the exclusion of an androgen producing tumor of the adrenal cortex. A high DHEA-S level may indicate an adrenal factor in androgen production, and if substantially elevated, the presence of an adrenocortical neoplasm. Tumor relevant DHEA-S values in women are those values exceeding 700 µg/dL DHEA-S. Patients with hyperprolactinemia have elevated DHEA-S levels.
LOINC—
SpecimenSerum (preferred) or plasma
Volume1.5 mL
Minimum volume0.7 mL ( Note: This volume does not allow for repeat testing.)
ContainerGel-barrier tube or red-top tube is preferred; green-top (lithium heparin-no gel) or K2EDTA-no gel are acceptable
Turnaround time3 - 5 days
Storage / transportRefrigerate.

Use

This test is used to identify the source of excessive androgen; it aids in the evaluation of androgen excess (hirsutism and/or virilization), including Stein-Leventhal syndrome and adrenocortical diseases, including congenital adrenal hyperplasia and adrenal tumor. DHEA-S is not increased with hypopituitarism; it is low in Addison disease. This test is used to identif i y the source of excessive androgen; it aids in the evaluation of androgen excess (hirsutism and/or virilization), including Stein-Leventhal syndrome and adrenocortical diseases, including congenital adrenal hyperplasia and adrenal tumor. DHEA-S is not increased with hypopituitarism; it is low in Addison disease. This test is…

Methodology

Ionify LC-MS/MS

Collection instructions

Gel-barrier tube or red-top tube: Centrifuge sample after clotting is complete. Red-top, green-top or K2EDTA: Transfer separated serum or plasma to a plastic transport tube.

Stability

TemperaturePeriod
Room temperature5 days (stability provided by manufacturer)
Refrigerated7 days (stability provided by manufacturer)
Frozen3 weeks (stability provided by manufacturer)
Freeze/thaw cyclesStable x1 (stability provided by manufacturer)

Causes for rejection

Unspun sample

Reference range

See table. Age Male (µg/dL) Female (µg/dL) <30 d 1 to 6 m 7 m to 1 y 2 to 5 y 6 to 7 y 8 to 10 y 11 to 12 y 13 to 14 y 15 to 16 y 17 to 18 y 19 to 20 y 21 to 30 y 31 to 40 y 41 to 50 y 51 to 60 y 61 to 70 y 71 to 80 y >80 y

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 82627

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation