Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › 17-OH Progesterone by Ionify LC-MS/MS

17-OH Progesterone by Ionify LC-MS/MS: Labcorp test 005134

Labcorp test 005134, CPT 83498. Specimen: Serum (preferred) or plasma. Turnaround: 3 - 5 days.

17-OH Progesterone by Ionify LC-MS/MS is Labcorp test code 005134, billed with CPT 83498. Specimen: Serum (preferred) or plasma. Turnaround time: 3 - 5 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, ARUP Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code005134
CPT83498 To be determined. Updates will be made when available. 83498 Share Print Updated on 10/19/2026 View Changes Test Details Specimen Requirements Test Details Methodology Ionify LC-MS/MS Ionify LC-MS/MS Result Turnaround Time 3 - 5 days 3 - 5 days Turnaround time is defined as the usual number of days from the date of pickup of a specimen for testing to when the result is released to the ordering provider. In some cases, additional time should be allowed for additional confirmatory or additional reflex tests. Testing schedules may vary. Use Markedly elevated in patients with congenital adrenal hyperplasia;evaluate hirsutism and/or infertility; assess or rule out certain adrenal or ovarian tumors with endocrine activity.
LOINC—
SpecimenSerum (preferred) or plasma
Volume1.5 mL
Minimum volume0.7 mL ( Note : This volume does not allow for repeat testing.)
ContainerGel-barrier or red-top tube is preferred; green-top (lithium heparin-no gel) or K2EDTA-no gel is acceptable Gel-barrier or red-top tube is preferred; green-top (lithium heparin-no gel) or K2EDTA-no gel are acceptable Gel-barrier or red-top tube is preferred; green-top (lithium heparin-no gel) or K2EDTA-no gel is acceptable
Turnaround time3 - 5 days 3 - 5 days
Storage / transportRefrigerate.

Use

Markedly elevated in patients with congenital adrenal hyperplasia;evaluate hirsutism and/or infertility; assess or rule out certain adrenal or ovarian tumors with endocrine activity.

Methodology

Ionify LC-MS/MS Ionify LC-MS/MS

Collection instructions

Gel-barrier or red-top tube: Centrifuge sample after clotting is complete. Red-top, green-top or K2 EDTA tube: Transfer separated serum or plasma to a plastic transport tube.

Stability

TemperaturePeriod
Room temperature5 days (stability provided by manufacturer)
Refrigerated14 days (stability provided by manufacturer)
Frozen12 weeks (stability provided by manufacturer)
Freeze/thaw cyclesStable x1 (stability provided by manufacturer)
TemperaturePeriod
Room temperature5 days (stability provided by manufacturer)
Refrigerated14 days (stability provided by manufacturer)
Frozen12 weeks (stability provided by manufacturer)
Freeze/thaw cyclesStable x1
TemperaturePeriod
Room temperature5 days (stability provided by manufacturer)
Refrigerated14 days (stability provided by manufacturer)
Frozen12 weeks (stability provided by manufacturer)
Freeze/thaw cyclesStable x1 (stability provided by manufacturer)

Causes for rejection

Unspun sample

Reference range

Age Male (ng/dL) Female (ng/dL) <7 d 8 to 30 d 1 to 6 m 7 to 11 m 1 to 3 y 4 to 5 y 6 to 7 y 8 y 9 y 10 to 11 y 12 to 16 y 17 y 18 to 19 y 20 to 40 y 41 to 50 y 51 to 55 y 56 to 60 y 61 to 65 y 66 to 70 y 71 to 80 y >80 y

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 83498

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation