Cyclic AMP, Plasma: Labcorp test 004984
Labcorp test 004984, CPT 82030. Specimen: Plasma, frozen. Turnaround: 4 - 9 days.
Also known as: cAMP, Plasma
Use
Determination of cAMP is useful in the clinical assessment of parathyroid function.
Methodology
Radioimmunoassay (RIA)
Collection instructions
Keep blood samples on ice and centrifuge as soon as possible. Separate plasma from cells and transfer to a plastic transport tube. Freeze immediately. To avoid delays in turnaround time when requesting multiple tests on frozen samples, please submit separate frozen specimens for each test requested.
Stability
| Temperature | Period |
|---|---|
| Frozen | 9 days |
| Freeze/thaw cycles | Stable x3 |
Patient preparation
Patient should have no radioactive isotopes administered within 48 hours prior to venipuncture.
Causes for rejection
Gross hemolysis; gross lipemia; nonfrozen specimen received; non-EDTA plasma specimen received
Reference range
13.9–25.1 pmol/L Reference interval was developed through Labcorp in-house study.
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|---|---|---|
| 004985 | Cyclic AMP, Plasma | pmol/mL | 25498-7 |
View this test on Labcorp's website → · Last checked 2026-11-29
Other tests billed with CPT 82030
Search the National Lab Test Directory · All Labcorp tests and CLIA locations