Labcorp test 004500, CPT 84146. Specimen: Serum (preferred) or plasma. Turnaround: 3 - 4 days.

Prolactin, Pituitary Macroadenoma, Serum is Labcorp test code 004500, billed with CPT 84146. Specimen: Serum (preferred) or plasma. Turnaround time: 3 - 4 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Michigan Medicine Laboratories (MLabs), Cleveland Clinic Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code004500
CPT84146(x2)
LOINC2842-3
SpecimenSerum (preferred) or plasma
Volume1.5 mL
Minimum volume1 mL ( Note : This volume does not allow for repeat testing.)
ContainerRed-top tube, gel-barrier tube, or green-top (lithium heparin) tube. Do not use oxalate, EDTA, or citrate plasma.
Turnaround time3 - 4 days
Storage / transportRefrigerate.

Use

Useful for quantifying prolactin in serum specimens where the high-dose hook effect is suspected (e.g., presence of pituitary tumor with symptoms of prolactinoma and lower than expected serum prolactin concentration).

Methodology

Electrochemiluminescence immunoassay (ECLIA) Prolactin is measured by electrochemiluminescence immunoassay (ECLIA) with Roche Cobas Prolactin II assay. The Roche Cobas Prolactin II assay demonstrates no high-dose hook effect at prolactin concentrations up to approximately 12,690 ng/mL. Samples are tested directly and after 100-fold with sample diluent. A high-dose hook effect is ruled out if the result generated from the diluted sample (after correcting for dilution) is not significantly greater than the result obtain from the undiluted sample. The 100-fold dilution will overcome a potential hook effect and can help to distinguish between a large prolactinoma and a large nonfunctioning…

Collection instructions

If a red-top tube or plasma tube is used, transfer separated serum or plasma to a plastic transport tube. Venipuncture itself can elevate prolactin level. Therefore, some recommend insertion of heparinized scalp vein followed by a 30-minute rest before sample is drawn. Draw between 8 a.m. and 10 a.m. (levels subsequently increase).

Stability

TemperaturePeriod
Room temperature7 days
Refrigerated14 days
Frozen14 days
Freeze/thaw cyclesStable x3

Reference range

• Male: 4.0−15.2 ng/mL • Female: 4.8−23.3 ng/mL

Special instructions

A pituitary adenoma should be identified by imaging studies prior to ordering this test.

Limitations

Modestly elevated prolactin may occur in patients with large nonfunctioning adenomas due to decreased dopamine, which inhibits prolactin secretion due to hypothalamic stalk dysfunction. In patients receiving therapy with high biotin doses (i.e., >5 mg/day), no sample should be taken until at least eight hours after the last biotin administration. As with all tests containing monoclonal mouse antibodies, erroneous findings may be obtained from samples taken from patients who have been treated with monoclonal mouse antibodies or who have received them for diagnostic purposes. In rare cases, interference due to extremely high titers of antibodies to ruthenium can occur. Extremely high titers…

LOINC map

Result codeResult nameUnitsResult LOINC
Prolactinng/mL2842-3
Prolactin on 1:100 Dilutionng/mL2842-3

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 84146

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation