Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Adrenocorticotropic Hormone (ACTH), Plasma

Adrenocorticotropic Hormone (ACTH), Plasma: Labcorp test 004440

Labcorp test 004440, CPT 82024. Specimen: Plasma, frozen. Turnaround: 1 - 2 days.

Adrenocorticotropic Hormone (ACTH), Plasma is Labcorp test code 004440, billed with CPT 82024. Specimen: Plasma, frozen. Turnaround time: 1 - 2 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, ARUP Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code004440
CPT82024 (per specimen)
LOINC2141-0
SpecimenPlasma, frozen
Volume0.8 mL
Minimum volume0.3 mL ( Note: This volume does not allow for repeat testing.)
ContainerPlastic or siliconized glass lavender-top (EDTA) tube
Turnaround time1 - 2 days
Storage / transportFreeze immediately.

Also known as: ACTH; Corticotropin

Use

This test is a pituitary function test useful in the differential diagnosis of Cushing syndrome, ectopic ACTH syndrome (e.g., carcinoma of lung, islet cell tumors, carcinoid tumors, medullary carcinoma of thyroid), Addison disease, hypopituitarism and ACTH-producing pituitary tumors (e.g., Nelson syndrome).

Methodology

Electrochemiluminescence immunoassay (ECLIA) This assay is performed on the Roche cobas instrument in multiple laboratories throughout Labcorp.

Collection instructions

ACTH should be drawn between 7 a.m. and 10 a.m. Collect into iced lavender-top (EDTA) tube, noting time of collection. Centrifuge immediately after collection and transfer plasma into a Labcorp PP transpak frozen purple tube with screw cap (Labcorp No. 49482). Freeze immediately and maintain frozen until tested. Contact Labcorp's supply department for special tubes. To avoid delays in turnaround time when requesting multiple tests on frozen samples, please submit separate frozen specimens for each test requested.

Stability

TemperaturePeriod
Room temperatureUnstable
RefrigeratedUnstable
Frozen14 days
Freeze/thaw cyclesStable x1

Causes for rejection

Thawed specimen; serum or heparinized plasma specimen; specimen collected in nonsiliconized glass tube

Reference range

7.2−63.3 pg/mL ( Note: For samples collected between 7 AM and 10 AM)

Special instructions

Instructions for suppression/stimulation tests involving ACTH measurement can be found in the online endocrine appendices ACTH Stimulation and Corticotropin-releasing Hormone Stimulation. This test may exhibit interference when sample is collected from a person who is consuming a supplement with a high dose of biotin (also termed as vitamin B7 or B8, vitamin H, or coenzyme R). It is recommended to ask all patients who may be indicated for this test about biotin supplementation. Patients should be cautioned to stop biotin consumption at least 72 hours prior to the collection of a sample.

Limitations

ACTH secretion is pulsatile so multiple specimen collections may be required. Collection in nonsiliconized tubes can result in falsely low results as ACTH adheres to glass. As with all tests containing monoclonal mouse antibodies, erroneous findings may be obtained from samples taken from patients who have been treated with monoclonal mouse antibodies or who have received them for diagnostic purposes. In rare cases, interference due to extremely high titers of antibodies to streptavidin and ruthenium can occur. The test contains additives, which minimize these effects.

LOINC map

Result codeResult nameUnitsResult LOINC
004441ACTH, Plasmapg/mL2141-0

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 82024

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation