Human Chorionic Gonadotropin (hCG), β-Subunit, Quantitative: Labcorp test 004416
Labcorp test 004416, CPT 84702. Specimen: Serum (preferred) or plasma. Turnaround: Within 1 day.
Human Chorionic Gonadotropin (hCG), β-Subunit, Quantitative is Labcorp test code 004416, billed with CPT 84702. Specimen: Serum (preferred) or plasma. Turnaround time: Within 1 day. Performing laboratory: Labcorp, CLIA
34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, ARUP Laboratories.
Test code004416
CPT84702
LOINC45194-8
SpecimenSerum (preferred) or plasma
Volume1 mL
Minimum volume0.7 mL ( Note: This volume does not allow for repeat testing.)
ContainerRed-top tube, gel-barrier tube or green-top (lithium heparin) tube. Do not use oxalate, EDTA or citrate plasma.
Turnaround timeWithin 1 day
Storage / transportRoom temperature
Also known as: hCG Quantitative; Human Chorionic Gonadotropin (hCG), Beta Subunit, Quantitative
Use
This assay is an immunoassay for the in vitro quantitative determination of the sum of human chorionic gonadotropin (hCG) plus the hCG beta-subunit in human serum and plasma. This assay is intended for the early detection of pregnancy.
Methodology
Electrochemiluminescence immunoassay (ECLIA)
This assay is performed on the Roche cobas instrument in multiple laboratories throughout Labcorp.
Collection instructions
If a red-top tube or plasma is used, transfer separated serum or plasma to a plastic transport tube.
Stability
| Temperature | Period |
|---|
| Room temperature | 14 days |
| Refrigerated | 14 days |
| Frozen | 14 days |
| Freeze/thaw cycles | Stable x3 |
Causes for rejection
Citrate plasma specimen; improper labeling
Reference range
See table.
Range (mIU/mL)
Weeks of pregnancy is defined as completed weeks beginning with the start of the last menstruation phase.
Male
0−3
Female
nonpregnant
0−5
postmenopausal
0−8
pregnant
Weeks Gestation
6−71
10−750
217−7138
158−31,795
3697−163,563
32,065−149,571
63,803−151,410
46,509−186,977
27,832−210,612
13,950−62,530
12,039−70,971
9040−56,451
8175−55,868
8099−58,176
Special instructions
Values obtained with different assay methods should not be used interchangeably in serial testing. It is recommended that only one assay method be used consistently to monitor each patient's course of therapy. This procedure does not provide serial monitoring; it is intended for one-time use only. If serial monitoring is required, please use the serial monitoring number 480038 to order.
This test may exhibit interference when sample is collected from a person who is consuming a supplement with a high dose of biotin (also termed as vitamin B7 or B8, vitamin H, or coenzyme R). It is recommended to ask all patients who may be indicated for this test about biotin supplementation. Patients should be cautioned to stop biotin consumption at least 72 hours prior to the collection of a sample.
Limitations
As with all tests containing monoclonal mouse antibodies, erroneous findings may be obtained from samples taken from patients who have been treated with monoclonal mouse antibodies or have received them for diagnostic purposes. In rare cases, interference due to extremely high titers of antibodies to streptavidin and ruthenium can occur. The test contains additives, which minimize these effects.
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|
| 004417 | hCG,Beta Subunit,Qnt,Serum | mIU/mL | 45194-8 |
View this test on Labcorp's website → · Last checked 2026-11-29
Other tests billed with CPT 84702
- Afp4® Screening - Quadruple Marker Test (AFP, hCG, uE3, Inhibin A)
LabcorpTest code 325CPT 82105, 82677, 84702, 86336Whole blood; serumTAT 2 - 5 days Turnaround time is defined as
- Beta hCG Quant Tumor Marker
Cleveland Clinic LaboratoriesTest code BHCGCPT 84702SerumTAT 2 - 3 days
- Beta HCG, Quantitative, Blood
Cleveland Clinic LaboratoriesTest code HCGQTCPT 84702PlasmaTAT 8 hours
- Beta-hCG, Quantitative (Pregnancy)
ARUP LaboratoriesTest code 3016579CPT 84702Serum separator tube. Also acceptable: Lavender (K2EDTA or K3EDTA), pink (K2EDTATAT Within 24 hours
- Beta-hCG, Quantitative (Tumor Marker)
ARUP LaboratoriesTest code 0070029CPT 84702Serum separator tube. Also acceptable: Lavender (K2EDTA or K3EDTA), pink (K2EDTATAT Within 24 hours
- Beta-hCG, Quantitative (Tumor Marker), CSF
ARUP LaboratoriesTest code 0020730CPT 84702CSF. Also acceptable: CSF collected in plain red or green (lithium heparin).TAT Within 24 hours
- Beta-hCG, Quantitative (Tumor Marker), CSF
Cleveland Clinic LaboratoriesTest code HCGCSFCPT 84702Cerebrospinal fluid (CSF)TAT 2 - 3 days
- First Trimester Screen With Nuchal Translucency
LabcorpTest code 017500CPT 81509, 84163, 84702, 86336SerumTAT 2 - 5 days
- FirstScreen® – First Trimester Screening
LabcorpTest code 315CPT 84163, 84702Whole blood, serum, or dried blood spotTAT 2 - 5 days Turnaround time is defined as
- Human Chorionic Gonadotropin (hCG), β-Subunit, Quantitative (Serial Monitor)
LabcorpTest code 480038CPT 84702TAT Within 1 day
- Integrated 2
LabcorpTest code 017170CPT 81511, 82105, 82677, 84702, 86336SerumTAT 2 - 5 days
- PrEP, Female, Injectable Baseline + HIV RNA
LabcorpTest code 254988CPT 84702, 86704, 86706, 86780, 86803, 87340, 87389, 87491, 87535, 87538, 87591Serum and first-void urine (patient should not have urinated for one hour prior TAT 2 - 3 days (testing performed daily)
- PrEP, Female, Injectable Monitor (No HIV RNA)
LabcorpTest code 254951CPT 84702, 86780, 87389, 87491, 87591Serum and first-void urine (patient should not have urinated for one hour prior TAT 2 - 3 days (testing performed daily)
- PrEP, Female, Injectable Monitor + HIV RNA
LabcorpTest code 254801CPT 84702, 86780, 87389, 87491, 87535, 87538, 87591Serum and first-void urine (patient should not have urinated for one hour prior TAT 2 - 3 days (testing performed daily)
- PrEP, Female, Oral Baseline + HIV RNA
LabcorpTest code 254855CPT 82565, 84702, 86704, 86706, 86780, 86803, 87340, 87389, 87491, 87535, 87538, 87591Serum and first-void urine (patient should not have urinated for one hour prior TAT 2 - 3 days (testing performed daily)
- PrEP, Female, Oral Monitor (No HIV RNA)
LabcorpTest code 254905CPT 84702, 86780, 87389, 87491, 87591Serum and first-void urine (patient should not have urinated for one hour prior TAT 2 - 3 days (testing performed daily)
- PrEP, Female, Oral Monitor + HIV RNA
LabcorpTest code 254880CPT 84702, 86780, 87389, 87491, 87535, 87538, 87591Serum and first-void urine (patient should not have urinated for one hour prior TAT 2 - 3 days (testing performed daily)
- Sequential 1
LabcorpTest code 017700CPT 81508, 84163, 84702SerumTAT 2 - 5 days
- Sequential 2
LabcorpTest code 017750CPT 81511, 82105, 82677, 84702, 86336SerumTAT 2 - 5 days
- Sequential Scn First Trimester
Cleveland Clinic LaboratoriesTest code SEQ1CPT 84163, 84702SerumTAT 3 - 6 days
- Sequential Screen Second Trimester
Cleveland Clinic LaboratoriesTest code SEQ2CPT 82105, 82677, 84702, 86336SerumTAT 3 - 6 days
- SequentialScreen Part 1
LabcorpTest code 335CPT 81508, 84163, 84702Whole blood, serum, or dried blood spotTAT 2 - 5 days
- SequentialScreen Part 2
LabcorpTest code 336CPT 81511, 82105, 82677, 84702, 86336Whole blood; serumTAT 2 - 5 days
- Serum Integrated 2
LabcorpTest code 017270CPT 81511, 82105, 82677, 84702, 86336SerumTAT 2 - 5 days
- Testicular Cancer Monitor Profile
LabcorpTest code 485151CPT 82105, 84702SerumTAT Within 1 day
- α-Fetoprotein (AFP) Tetra Profile
LabcorpTest code 017319CPT 81511, 82105, 82677, 84702, 86336SerumTAT 2 - 5 days
- First Trimester Screen With Nuchal Translucency
LabcorpTest code 017500Women's HealthCPT 81509, 84163, 84702, 86336SerumTAT 2 - 5 days
- Human Chorionic Gonadotropin (hCG), β-Subunit, Quantitative
LabcorpTest code 004416Women's HealthCPT 84702Serum (preferred) or plasmaTAT Within 1 day
- Integrated 2
LabcorpTest code 017170Women's HealthCPT 81511, 82105, 82677, 84702, 86336SerumTAT 2 - 5 days
- Sequential 1
LabcorpTest code 017700Women's HealthCPT 81508, 84163, 84702SerumTAT 2 - 5 days
Search the National Lab Test Directory · All Labcorp tests and CLIA locations
Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code.
Submit your lab's test menu → Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation