Labcorp test 004389, CPT 82626. Specimen: Serum (preferred) or plasma. Turnaround: 3 - 5 days.

DHEA by Ionify LC-MS/MS is Labcorp test code 004389, billed with CPT 82626. Specimen: Serum (preferred) or plasma. Turnaround time: 3 - 5 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Cleveland Clinic Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code004389
CPT82626
LOINC2193-1
SpecimenSerum (preferred) or plasma
Volume1.5 mL
Minimum volume0.7 mL ( Note: This volume does not allow for repeat testing.)
ContainerGel-barrier tube or red-top tube is preferred. Green-top (lithium heparin-no gel) is acceptable.
Turnaround time3 - 5 days
Storage / transportSample must be refrigerated. Freeze if unable to maintain refrigerated.

Also known as: DHEA; unconjugated DHEA

Use

This test is used to evaluate adrenal carcinomas that frequently secrete large amounts of dehydroepiandrosterone (DHEA).

Methodology

Ionify LC-MS/MS

Collection instructions

Gel-barrier tube or red-top tube: Centrifuge sample after clotting is complete. Red-top tube or green-top tube: Transfer separated serum or plasma to a plastic transport tube.

Stability

TemperaturePeriod
Room temperatureUnstable (stability provided by manufacturer or literature reference)
Refrigerated7 days (stability provided by manufacturer or literature reference)
Frozen12 weeks (stability provided by manufacturer or literature reference)
Freeze/thaw cyclesStable x1 (stability provided by manufacturer or literature reference)

Causes for rejection

Shipped or received in lab at room temperature, unspun sample

Reference range

See table. Age Male (ng/mL) Female (ng/mL) <2 y 0.24–2.89 0.24–2.89 2 to 4 y 0.22–2.12 0.22–2.12 5 to 7 y 0.31–2.78 0.31–2.78 8 to 10 y 0.38–3.15 0.47–3.40 11 to 12 y 0.49–3.45 0.72–4.74 13 to 14 y 0.64–3.94 1.03–6.09 15 to 16 y 0.92–5.21 1.22–7.05 17 to 19 y 1.27–6.29 1.43–8.02 20 y 1.53–6.43 1.49–8.35 21 to 30 y 1.23–6.22 1.32–7.18 31 to 40 y 0.84–4.92 0.90–5.30 41 to 50 y 0.56–3.93 0.61–4.33 51 to 60 y 0.37–3.38 0.43–3.75 61 to 70 y 0.23–2.61 0.34–3.53 71 to 80 y 0.25–2.26 0.29–2.85 >80 y 0.16–1.49 0.24–2.08

LOINC map

Result codeResult nameUnitsResult LOINC
004393DHEA by Ionify LC-MS/MSng/mL2193-1

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 82626

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation