Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Thyroid-stimulating Hormone (TSH)

Thyroid-stimulating Hormone (TSH): Labcorp test 004259

Labcorp test 004259, CPT 84443. Specimen: Serum (preferred) or plasma. Turnaround: Within 1 day.

Thyroid-stimulating Hormone (TSH) is Labcorp test code 004259, billed with CPT 84443. Specimen: Serum (preferred) or plasma. Turnaround time: Within 1 day. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Cleveland Clinic Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code004259
CPT84443
LOINC11580-8
SpecimenSerum (preferred) or plasma
Volume1 mL
Minimum volume0.7 mL ( Note: This volume does not allow for repeat testing.)
ContainerRed-top tube, gel-barrier tube or green-top (lithium heparin) tube. Do not use oxalate, EDTA or citrate plasma.
Turnaround timeWithin 1 day
Storage / transportRoom temperature

Also known as: Third-generation TSH; Thyrotropin

Use

This is a thyroid function test that is used for investigation of low thyroxine (T 4 ) result; the differential diagnosis of primary hypothyroidism from normal and the differential diagnosis of primary hypothyroidism from pituitary/hypothalamic hypothyroidism. TSH is high in primary hypothyroidism. Low TSH occurs in hyperthyroidism. Evaluation of therapy in hypothyroid patients receiving various thyroid hormone preparations: Low values are found in states of excessive thyroid replacement. Normal result on a sensitive TSH assay is acceptable evidence of adequate thyroid replacement. Follow-up of patients who have had hyperthyroidism treated with radioiodine or surgery. Follow-up low T 4…

Methodology

Electrochemiluminescence immunoassay (ECLIA) This assay is performed on the Roche cobas instrument in multiple laboratories throughout Labcorp.

Collection instructions

If a red-top tube or plasma is used, transfer separated serum or plasma to a plastic transport tube.

Stability

TemperaturePeriod
Room temperature14 days
Refrigerated14 days
Frozen14 days
Freeze/thaw cyclesStable x3

Causes for rejection

Citrate plasma specimen; improper labeling

Reference range

See table. Age Range (μIU/mL) 0 to 6 d 0.700−15.200 7 d to 3 m 0.720−11.000 3 m 1 d to 12 m 0.730−8.350 1 to 5 y 0.700−5.970 6 to 10 y 0.600−4.840 >10 y 0.450−4.500

Special instructions

This test may exhibit interference when sample is collected from a person who is consuming a supplement with a high dose of biotin (also termed as vitamin B7 or B8, vitamin H, or coenzyme R). It is recommended to ask all patients who may be indicated for this test about biotin supplementation. Patients should be cautioned to stop biotin consumption at least 72 hours prior to the collection of a sample.

Limitations

Spurious increase from antibovine TSH antibodies by double-antibody technique has been reported. TSH may be affected by glucocorticoids, dopamine, and by severe illness, and these remain limitations even for the new, sensitive TSH assays. TSH suppression in hypothyroidism with severe illness has been reported with TSH increase with recovery. Normal TSH levels in the presence of hypothyroidism have been reported with head injury. Iopanoic acid, ipodate, and an antiarrhythmic drug, amiodarone, cause changes in thyroid test results including increases in T 4 , free T 4 , and TSH and decreases of T 3 . TSH is not elevated in secondary hypothyroidism. Probably no single test, even the sensitive…

LOINC map

Result codeResult nameUnitsResult LOINC
004264TSHuIU/mL11580-8

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 84443

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation