Labcorp test 003038, CPT 81003. Specimen: Urine (random). Turnaround: Within 1 day.

Urinalysis, Routine With Microscopic Examination on Positives is Labcorp test code 003038, billed with CPT 81003. Specimen: Urine (random). Turnaround time: Within 1 day. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code003038
CPT81003
LOINC20454-5, 24357-6, 5767-9, 5778-6, 5799-2, 5803-2, 5811-5
SpecimenUrine (random)
Volume3-9 mL (Vacutainer® red/yellow urine transport tube) (preferred) or 2 mL or greater (non-preserved urine)
Minimum volume3 mL (Vacutainer® red/yellow urine transport tube) (preferred) or 2 mL (non-preserved urine) ( Note: This volume does not allow for repeat testing.)
ContainerVacutainer® red/yellow urine transport tube (preferred) or urine bottle/urine transport tube (non-preserved)
Turnaround timeWithin 1 day
Storage / transportVacutainer® red/yellow urine transport tube: room temperature for up to 72 hours Urine bottle/urine transport tube (non-preserved): room temperature up to 2 hours and refrigerated up to 48 hours

Test includes

Color, appearance, specific gravity, pH, protein, glucose, ketones, occult blood, leukocyte esterase, nitrite, bilirubin, and urobilinogen. These tests are done on all routine urinalysis ordered and if protein, leukocyte, occult blood, and nitrites are all negative, microscopic examination is not performed; just the above parameters are reported.

Use

Detect abnormalities of urine; diagnose and manage renal diseases, urinary tract infection, urinary tract neoplasms, systemic diseases, and inflammatory or neoplastic diseases adjacent to the urinary tract

Methodology

Reagent strip

Collection instructions

A voided specimen is usually suitable. If the specimen is likely to be contaminated, a clean-catch, midstream specimen is desirable.

Causes for rejection

Quantity not sufficient for analysis; improper labeling; tubes with boric acid or tartaric acid (e.g., BD gray-top C&S tube); Labcorp red-top C&S tube; Boricon, Bortiex, or Boricult yellow-top C&S tubes; urine transport tube with Triclosan; specimen received in Vacutainer® red/yellow urine transport tube more than 72 hours old; specimen received in urine cup stored at room temperature greater than 2 hours old; specimen received in urine cup refrigerated more than 48 hours old; frozen specimens; Vacutainer® red/yellow urine transport tube less than 3 mL or greater than 9 mL

Limitations

Insufficient volume may limit the extent of procedures performed. Metabolites of Pyridium® may interfere with the dipstick reactions by producing color interference. High vitamin C intake may cause an underestimate of glucosuria, or a false-negative nitrite test. Survival of WBCs is decreased by low osmolality, alkalinity, and lack of refrigeration. Sperm is not reported in routine urinalysis exams. Spermatozoa may be seen in male urine related to recent or retrograde ejaculation. For sperm reporting in males only, order Postejaculatory Urine Microscopic Examination for Sperm [133116] .

LOINC map

Result codeResult nameUnitsResult LOINC
013060Specific Gravity5811-5
013078pH5803-2
013045Urine-Color5778-6
013052Appearance5767-9
013185WBC Esterase5799-2
013094Protein20454-5

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 81003

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation