Carbohydrate Antigen (CA) 19-9: Labcorp test 002261
Labcorp test 002261, CPT 86301. Specimen: Serum. Turnaround: Within 1 day.
Also known as: CA 19-9
Use
Monitor gastrointestinal, pancreatic, liver, and colorectal malignancies
Methodology
Electrochemiluminescence immunoassay (ECLIA)
Collection instructions
If a red-top tube is used, transfer separated serum to a plastic transport tube.
Stability
| Temperature | Period |
|---|---|
| Room temperature | 14 days |
| Refrigerated | 14 days |
| Frozen | 14 days |
| Freeze/thaw cycles | Stable x3 |
Causes for rejection
Citrate plasma specimen; improper labeling
Reference range
0−35 units/mL
Special instructions
Values obtained with different assay methodologies should not be used interchangeably in serial testing. It is recommended that only one assay method be used consistently to monitor a patient's course of therapy. This procedure does not provide serial monitoring; it is intended for one-time use only. If serial monitoring required, please use the serial monitoring number 480053 to order. This test may exhibit interference when sample is collected from a person who is consuming a supplement with a high dose of biotin (also termed as vitamin B7 or B8, vitamin H, or coenzyme R). It is recommended to ask all patients who may be indicated for this test about biotin supplementation. Patients should be cautioned to stop biotin consumption at least 72 hours prior to the collection of a sample.
Limitations
The measured CA 19-9 value of a patient's sample can vary depending on the testing procedure used. CA 19-9 values determined on patient samples by different testing procedures cannot be directly compared with one another and could be the cause of erroneous medical interpretations. The determination of CA 19-9 cannot be used for the early detection of pancreatic carcinoma. Three percent to 7% of the population have the Lewis a-negative/b-negative blood group configuration and are unable to express the mucin with the reactive determinant CA 19-9. Patients known to be genotypically negative for Lewis blood group antigens will be unable to produce the CA 19-9 antigen even in the presence of…
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|---|---|---|
| 002282 | CA 19-9 | U/mL | 24108-3 |
View this test on Labcorp's website → · Last checked 2026-11-29
Other tests billed with CPT 86301
- CA 19-9
- CA 19-9
- Cancer Antigen-GI (CA 19-9)
- Cancer Antigen-GI (CA 19-9), Body Fluid
- Carbohydrate Antigen (CA) 19-9 (Serial Monitor)
Search the National Lab Test Directory · All Labcorp tests and CLIA locations
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation