Angiotensin II: Labcorp test 002180
Labcorp test 002180, CPT 82163. Specimen: Plasma, frozen. Turnaround: 4 – 14 days.
Use
The renin-angiotensin aldosterone hormonal cascade that regulates blood pressure and water (fluid) balance begins with the biosynthesis of renin by the juxtaglomerular cells that line the afferent (and occasionally efferent) arteriole of the renal glomerulus. A drop in blood pressure decreases the perfusion of the juxtaglomerular apparatus, resulting in the release of the enzyme renin. Renin proceeds to cleave angiotensinogen to produce angiotensin I. Angiotensin I is in turn converted to angiotensin II by angiotensin-converting enzyme (ACE), which is found mainly in lung capillaries. Angiotensin II is the major bioactive product of the renin-angiotensin system, binding to receptors on…
Methodology
Radioimmunoassay (RIA)
Collection instructions
Trasylol® kits may be ordered through the PeopleSoft system (LabCorp N° 33328). Using a chilled 6-mL lavender-top (EDTA) tube taken from the kit, collect a whole blood specimen. Mix the specimen several times by inverting the EDTA collection tube. After removing the cap from the EDTA draw tube, take one of the sterile, Beral pipettes (from under the gray foam), and add 0.25 mL Trasylol® to the EDTA tube. Recap the EDTA tube and invert several times to mix well. Centrifuge the EDTA tube to separate the plasma from the cells, and immediately transfer the plasma into one of the brown screw-cap transfer tubes provided in the kit. There should be a "Trasylol® Added" label affixed to the brown transport tubes. Cap and freeze the labeled transport tube containing the EDTA plasma with Trasylol® added. To avoid delays in turnaround time when requesting multiple test on frozen samples, please submit separate frozen specimens for each test requested.
Stability
| Temperature | Period |
|---|---|
| Room temperature | 1 hour |
| Refrigerated | 1 hour |
| Frozen | 14 days |
| Freeze/thaw cycles | Stable x3 |
Patient preparation
Patient must not have received radioactive substances 24 hours prior to test. Patient should be fasting.
Causes for rejection
Sample not collected with Trasylol®; sample not submitted in tube with Trasylol label, gross hemolysis; recently administered radioisotopes; specimen not received frozen; serum, sodium citrate, or heparinized plasma specimen; lipemia
Special instructions
Contact the LabCorp supply department for collection kit.
Limitations
Results for this test are for research purposes only by the assay's manufacturer. The performance characteristics of this product have not been established. Results should not be used as a diagnostic procedure without confirmation of the diagnosis by another medically established diagnostic product or procedure.
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|---|---|---|
| 002181 | Angiotensin II | pg/mL | 1860-6 |
View this test on Labcorp's website → · Last checked 2026-11-29
Other tests billed with CPT 82163
Search the National Lab Test Directory · All Labcorp tests and CLIA locations
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.