Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Angiotensin II

Angiotensin II: Labcorp test 002180

Labcorp test 002180, CPT 82163. Specimen: Plasma, frozen. Turnaround: 4 – 14 days.

Angiotensin II is Labcorp test code 002180, billed with CPT 82163. Specimen: Plasma, frozen. Turnaround time: 4 – 14 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, ARUP Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code002180
CPT82163
LOINC1860-6
SpecimenPlasma, frozen
Volume3 mL
Minimum volume1.5 mL ( Note: This volume does not allow for repeat testing.)
ContainerLavender-top (EDTA) tube with Trasylol®
Turnaround time4 – 14 days
Storage / transportFreeze.

Use

The renin-angiotensin aldosterone hormonal cascade that regulates blood pressure and water (fluid) balance begins with the biosynthesis of renin by the juxtaglomerular cells that line the afferent (and occasionally efferent) arteriole of the renal glomerulus. A drop in blood pressure decreases the perfusion of the juxtaglomerular apparatus, resulting in the release of the enzyme renin. Renin proceeds to cleave angiotensinogen to produce angiotensin I. Angiotensin I is in turn converted to angiotensin II by angiotensin-converting enzyme (ACE), which is found mainly in lung capillaries. Angiotensin II is the major bioactive product of the renin-angiotensin system, binding to receptors on…

Methodology

Radioimmunoassay (RIA)

Collection instructions

Trasylol® kits may be ordered through the PeopleSoft system (LabCorp N° 33328). Using a chilled 6-mL lavender-top (EDTA) tube taken from the kit, collect a whole blood specimen. Mix the specimen several times by inverting the EDTA collection tube. After removing the cap from the EDTA draw tube, take one of the sterile, Beral pipettes (from under the gray foam), and add 0.25 mL Trasylol® to the EDTA tube. Recap the EDTA tube and invert several times to mix well. Centrifuge the EDTA tube to separate the plasma from the cells, and immediately transfer the plasma into one of the brown screw-cap transfer tubes provided in the kit. There should be a "Trasylol® Added" label affixed to the brown transport tubes. Cap and freeze the labeled transport tube containing the EDTA plasma with Trasylol® added. To avoid delays in turnaround time when requesting multiple test on frozen samples, please submit separate frozen specimens for each test requested.

Stability

TemperaturePeriod
Room temperature1 hour
Refrigerated1 hour
Frozen14 days
Freeze/thaw cyclesStable x3

Patient preparation

Patient must not have received radioactive substances 24 hours prior to test. Patient should be fasting.

Causes for rejection

Sample not collected with Trasylol®; sample not submitted in tube with Trasylol label, gross hemolysis; recently administered radioisotopes; specimen not received frozen; serum, sodium citrate, or heparinized plasma specimen; lipemia

Special instructions

Contact the LabCorp supply department for collection kit.

Limitations

Results for this test are for research purposes only by the assay's manufacturer. The performance characteristics of this product have not been established. Results should not be used as a diagnostic procedure without confirmation of the diagnosis by another medically established diagnostic product or procedure.

LOINC map

Result codeResult nameUnitsResult LOINC
002181Angiotensin IIpg/mL1860-6

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 82163

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation