Sound Lab Consultants › National Lab Test Directory › Labcorp › Carcinoembryonic Antigen (CEA)

Carcinoembryonic Antigen (CEA) (Women's Health): Labcorp test 002139

Labcorp test 002139, CPT 82378. Specimen: Serum. Turnaround: Within 1 day.

Carcinoembryonic Antigen (CEA) is Labcorp test code 002139, billed with CPT 82378. Specimen: Serum. Turnaround time: Within 1 day. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Michigan Medicine Laboratories (MLabs), ARUP Laboratories, Cleveland Clinic Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code002139 (Women's Health)
CPT82378
LOINC2039-6
SpecimenSerum
Volume1 mL
Minimum volume0.7 mL ( Note: This volume does not allow for repeat testing.)
ContainerGel-barrier tube (preferred) or red-top tube
Turnaround timeWithin 1 day
Storage / transportRoom temperature

Use

This assay is intended for the in vitro quantitative determination of carcinoembryonic antigen in human serum and plasma. The Elecsys CEA assay is further indicated for serial measurement of CEA to aid in the management of cancer patients. The main indication for CEA determinations is the follow-up and therapy-management of colorectal carcinoma.

Methodology

Electrochemiluminescence immunoassay (ECLIA)

Collection instructions

If a red-top tube is used, transfer separated serum to a plastic transport tube.

Stability

TemperaturePeriod
Room temperature7 days
Refrigerated14 days
Frozen14 days
Freeze/thaw cyclesStable x3

Causes for rejection

Citrate plasma specimen; improper labeling

Reference range

Range: 0−4.7 ng/mL; nonsmoker: <3.9 ng/mL; smoker: <5.6 ng/mL

Special instructions

Values obtained with different assay methodologies should not be used interchangeably in serial testing. It is recommended that only one assay method be used consistently to monitor each patient's course of therapy. This procedure does not provide serial monitoring; it is intended for one-time use only. If serial monitoring is required, please order the serial monitoring test ( 480095 ). This test may exhibit interference when sample is collected from a person who is consuming a supplement with a high dose of biotin (also termed as vitamin B7 or B8, vitamin H, or coenzyme R). It is recommended to ask all patients who may be indicated for this test about biotin supplementation. Patients should be cautioned to stop biotin consumption at least 72 hours prior to the collection of a sample.

Limitations

CEA determinations are not recommended for cancer screening in the general population. CEA concentrations within the normal range do not exclude the possible presence of a malignant disease. The measured CEA value of a patient's sample can vary depending on the test procedure used. CEA values determined on patient samples by different test procedures cannot be directly compared with one another and could be the cause of erroneous medical interpretations. As with all tests containing monoclonal mouse antibodies, erroneous findings may be obtained from samples taken from patients who have been treated with monoclonal mouse antibodies or have received them for diagnostic purposes. In rare…

LOINC map

Result codeResult nameUnitsResult LOINC
002169CEAng/mL2039-6

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 82378

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation