Vitamin A and Carotene: Labcorp test 001750
Labcorp test 001750, CPT 82380, 84590. Specimen: Serum; beta carotene protected from light. Turnaround: 4 - 6 days.
Vitamin A and Carotene is Labcorp test code 001750, billed with CPT 82380, 84590. Specimen: Serum; beta carotene protected from light. Turnaround time: 4 - 6 days. Performing laboratory: Labcorp, CLIA
34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, ARUP Laboratories.
Test code001750
CPT82380; 84590
LOINC2053-7, 2923-1
SpecimenSerum; beta carotene protected from light
VolumeTwo aliquots: 0.8 mL each
Minimum volumeTwo aliquots: 0.4 mL each ( Note: This volume does not allow for repeat testing.)
ContainerVitamin A can be shipped in red-top tube or gel-barrier tube; beta carotene should be shipped in amber plastic transport tube with amber top. (If amber tubes are unavailable, cover standard transport tubes completely, top and bottom, with aluminum foil. Identify specimens with the patient's name directly on the containers and on the outside of the aluminum foil. Secure with tape.) For amber plastic transport tube and amber-top, order LabCorp No. 23598.
Turnaround time4 - 6 days
Storage / transportRoom temperature. Beta carotene should be light-protected.
Use
A combination of a low serum carotene level and a low vitamin A suggests inadequate vitamin A nutrition.
Methodology
Vitamin A: Liquid chromatography/tandem mass spectrometry (LC/MS-MS); Carotene: High-pressure liquid chromatography (HPLC) with UV detection
Collection instructions
Transfer specimens to separate amber plastic transport tubes. Beta carotene should be shipped in amber plastic transport tube with amber top.
Stability
| Temperature | Period |
|---|
| Room temperature | 14 days |
| Refrigerated | 14 days |
| Frozen | 14 days |
| Freeze/thaw cycles | Stable x3 |
Patient preparation
Patient should abstain from alcohol for 24 hours prior to collection. For those who are younger than six months, draw prior to next feeding. Blood should be collected before breakfast in the morning and prior to any medication.
Causes for rejection
Beta carotene specimen not protected from light; sample type other than serum received
Special instructions
Patients must fast a minimum of eight hours. No foods containing vitamin A or carotene should be ingested in the previous 48 hours by patients older than six months. For those who are younger than six months, the period is 24 hours.
Limitations
This test was developed and its performance characteristics determined by Labcorp. It has not been cleared or approved by the Food and Drug Administration.
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|
| Carotene, Beta | ug/dL | | 2053-7 |
| Vitamin A | ug/dL | | 2923-1 |
View this test on Labcorp's website → · Last checked 2026-11-29
Other tests billed with CPT 82380, 84590
- Carotene
Cleveland Clinic LaboratoriesTest code CAROTCPT 82380SerumTAT 2 - 5 days
- Carotene, Serum Total
ARUP LaboratoriesTest code 0080055CPT 82380Serum separator tube (SST) or plain red.TAT 1-4 days
- Carotene, β
LabcorpTest code 001529CPT 82380Serum, protected from lightTAT 3 - 6 days
- Vitamin A, E, and β-Carotene Profile
LabcorpTest code 144057CPT 82380, 84446, 84590Serum, β-Carotene protected from lightTAT 4 - 7 days
- Post-Bariatric Surgery Comprehensive Profile
LabcorpTest code 259090CPT 80053, 80061, 82306, 82390, 82525, 82607, 82728, 82746, 83036, 83540, 83550, 83921, 83970, 84238, 84425, 84443, 84590, 84630, 85027Serum, whole blood, plasmaTAT 5 - 7 days
- Post-Bariatric Surgery Micronutrient Profile
LabcorpTest code 259129CPT 82306, 82310, 82390, 82525, 82607, 82728, 82746, 83540, 83550, 84238, 84425, 84590, 84630, 85025Serum, whole blood, plasmaTAT 3 - 5 days
- Pre-Bariatric Surgery Comprehensive Profile
LabcorpTest code 259141CPT 80053, 80061, 82306, 82390, 82525, 82607, 82728, 82746, 83036, 83540, 83550, 83921, 84425, 84443, 84466, 84590, 84630, 85027Serum, whole blood, plasmaTAT 5 - 7 days
- Vitamin A
LabcorpTest code 017509CPT 84590SerumTAT 4 - 5 days
- Vitamin A (Retinol), Serum or Plasma
Cleveland Clinic LaboratoriesTest code VITACPT 84590PlasmaTAT 2 - 5 days
- Vitamin A (Retinol), Serum or Plasma
ARUP LaboratoriesTest code 0080525CPT 84590Green (sodium or lithium heparin), plasma separator tube, or serum separator tubTAT 1-4 days
- Vitamin A and E
LabcorpTest code 144039CPT 84446, 84590SerumTAT 4 - 6 days
Search the National Lab Test Directory · All Labcorp tests and CLIA locations
Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code.
Submit your lab's test menu → Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation