Sound Lab Consultants › National Lab Test Directory › Labcorp › Magnesium

Magnesium (Women's Health): Labcorp test 001537

Labcorp test 001537, CPT 83735. Specimen: Serum (preferred) or plasma. Turnaround: Within 1 day.

Magnesium is Labcorp test code 001537, billed with CPT 83735. Specimen: Serum (preferred) or plasma. Turnaround time: Within 1 day. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Cleveland Clinic Laboratories, Michigan Medicine Laboratories (MLabs).
LaboratoryLabcorp
CLIA number34D0655059
Test code001537 (Women's Health)
CPT83735
LOINC19123-9
SpecimenSerum (preferred) or plasma
Volume1 mL
Minimum volume0.7 mL ( Note: This volume does not allow for repeat testing.)
ContainerRed-top tube, gel-barrier tube, or green-top (lithium heparin) tube. Do not use oxalate, EDTA, or citrate plasma.
Turnaround timeWithin 1 day
Storage / transportMaintain specimen at room temperature.

Use

Magnesium deficiency produces neuromuscular disorders. It may cause weakness, tremors, tetany, and convulsions. Hypomagnesemia is associated with hypocalcemia, hypokalemia, long-term hyperalimentation, intravenous therapy, diabetes mellitus, especially during treatment of ketoacidosis; alcoholism and other types of malnutrition; malabsorption; hyperparathyroidism; dialysis; pregnancy; and hyperaldosteronism. Renal loss of magnesium occurs with cis-platinum therapy. Alfrey also adds amphotericin toxicity to the causes of hypomagnesemia. Magnesium deficiency is described with cardiac arrhythmias. The concept that magnesium deficiency may cause arrhythmias is repeatedly expressed. Increased…

Methodology

Colorimetric

Collection instructions

Separate serum or plasma from cells within 45 minutes of collection.

Stability

TemperaturePeriod
Room temperature14 days
Refrigerated14 days
Frozen14 days
Freeze/thaw cyclesStable x3

Causes for rejection

EDTA or citrate plasma specimen

Limitations

Hemolysis will yield elevated results as levels in erythrocytes are two to three times higher than serum. Bilirubin may cause falsely low values.

LOINC map

Result codeResult nameUnitsResult LOINC
001537Magnesiummg/dL19123-9

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 83735

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation