Labcorp test 001339, CPT 83540. Specimen: Serum (preferred) or plasma (lithium heparin only). EDTA plasma causes decreased results.. Turnaround: Within 1 day.
Iron is Labcorp test code 001339, billed with CPT 83540. Specimen: Serum (preferred) or plasma (lithium heparin only). EDTA plasma causes decreased results.. Turnaround time: Within 1 day. Performing laboratory: Labcorp, CLIA
34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, ARUP Laboratories.
Test code001339
CPT83540
LOINC2498-4
SpecimenSerum (preferred) or plasma (lithium heparin only). EDTA plasma causes decreased results.
Volume1 mL
Minimum volume0.7 mL ( Note: This volume does not allow for repeat testing.)
ContainerRed-top tube, gel-barrier tube, or green-top (lithium heparin) tube. Do not use oxalate, EDTA, or citrate plasma.
Turnaround timeWithin 1 day
Storage / transportMaintain specimen at room temperature.
Aid in the evaluation of a number of conditions involving red cell production and destruction, iron metabolism, or iron transport
Separate serum or plasma from cells within 45 minutes of collection.
Severe hemolysis; improper labeling; improper collection; EDTA or oxalate plasma specimens
See table.
Male
Range (μg/dL)
0 to 30 d
35−160
1 m to 1 y
18−126
2 to 12 y
28−147
13 to 17 y
26−169
>17 y
38−169
Female
Range (μg/dL)
0 to 30 d
27−133
1 m to 1 y
18−126
2 to 12 y
28−147
13 to 17 y
26−169
18 to 60 y
27−159
>60 y
27−139
- Anemia Profile A
LabcorpTest code 030577CPT 83540, 83550, 85025, 85045Serum and whole bloodTAT Within 1 day
- Anemia Profile B
LabcorpTest code 042077CPT 82607, 82728, 82746, 83540, 83550, 85025, 85045Serum and whole bloodTAT Within 1 day
- Iron
Cleveland Clinic LaboratoriesTest code IRN1CPT 83540PlasmaTAT 8 hours
- Iron and Iron Binding Capacity
ARUP LaboratoriesTest code 0020420CPT 83540, 83550Plasma separator, Serum Separator Tube (SST), or green (lithium heparin).TAT Within 24 hours
- Iron and TIBC
Cleveland Clinic LaboratoriesTest code IRONCPT 83540, 83550PlasmaTAT 8 hours
- Iron and Total Iron-binding Capacity (TIBC)
LabcorpTest code 001321CPT 83540, 83550Serum (preferred) or plasma (lithium heparin only). EDTA plasma causes decreasedTAT Within 1 day
- Iron, Liver
ARUP LaboratoriesTest code 0028250CPT 83540Liver tissue obtained with an 18 gauge needle.TAT 3-10 days
- Iron, Liver
Cleveland Clinic LaboratoriesTest code LIVIROCPT 83540Tissue, liverTAT 4 - 11 days
- Iron, Plasma or Serum
ARUP LaboratoriesTest code 0020037CPT 83540Plasma separator tube, serum separator tube, or green (lithium heparin).TAT Within 24 hours
- Post-Bariatric Surgery Comprehensive Profile
LabcorpTest code 259090CPT 80053, 80061, 82306, 82390, 82525, 82607, 82728, 82746, 83036, 83540, 83550, 83921, 83970, 84238, 84425, 84443, 84590, 84630, 85027Serum, whole blood, plasmaTAT 5 - 7 days
- Post-Bariatric Surgery Micronutrient Profile
LabcorpTest code 259129CPT 82306, 82310, 82390, 82525, 82607, 82728, 82746, 83540, 83550, 84238, 84425, 84590, 84630, 85025Serum, whole blood, plasmaTAT 3 - 5 days
- Pre-Bariatric Surgery Comprehensive Profile
LabcorpTest code 259141CPT 80053, 80061, 82306, 82390, 82525, 82607, 82728, 82746, 83036, 83540, 83550, 83921, 84425, 84443, 84466, 84590, 84630, 85027Serum, whole blood, plasmaTAT 5 - 7 days
- Anemia Profile B
LabcorpTest code 042077Women's HealthCPT 82607, 82728, 82746, 83540, 83550, 85025, 85045Serum and whole bloodTAT Within 1 day
- Iron and Total Iron-binding Capacity (TIBC)
LabcorpTest code 001321Women's HealthCPT 83540, 83550Serum (preferred) or plasma (lithium heparin only). EDTA plasma causes decreasedTAT Within 1 day
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.