Labcorp test 001107, CPT 84075. Specimen: Serum (preferred) or plasma. Turnaround: Within 1 day.

Alkaline Phosphatase is Labcorp test code 001107, billed with CPT 84075. Specimen: Serum (preferred) or plasma. Turnaround time: Within 1 day. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, ARUP Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code001107 (Women's Health)
CPT84075
LOINC6768-6
SpecimenSerum (preferred) or plasma
Volume1 mL
Minimum volume0.7 mL ( Note: This volume does not allow for repeat testing.)
ContainerRed-top tube, gel-barrier tube, or green-top (lithium heparin) tube; do not use oxalate, EDTA or citrate plasma
Turnaround timeWithin 1 day
Storage / transportRoom temperature

Use

Causes of high alkaline phosphatase include bone growth, healing fracture, acromegaly, osteogenic sarcoma, liver or bone metastases, leukemia, myelofibrosis, and rarely myeloma. Alkaline phosphatase is used as a tumor marker. In rickets and osteomalacia, serum calcium and phosphorus are low to normal, and alkaline phosphatase may be normal or increased. Hypervitaminosis D may cause elevations in alkaline phosphatase. In Paget disease of bone there is often isolated elevation of serum alkaline phosphatase. Some of the highest levels of serum ALP are seen in Paget disease. Hyperthyroidism, by its effects upon bone, may elevate alkaline phosphatase. There is evidence that thyroid hormone (T 3…

Methodology

Kinetic

Collection instructions

Separate serum or plasma from cells within 45 minutes of collection. If a red-top tube or green-top tube is used, transfer separated serum or plasma to a plastic transport tube.

Stability

TemperaturePeriod
Room temperature14 days
Refrigerated14 days
Frozen14 days
Freeze/thaw cyclesStable x3

Causes for rejection

Hemolysis; plasma specimen; specimen collected in EDTA tube; improper labeling

Special instructions

Values obtained with different assay methods should not be used interchangeably in serial testing. It is recommended that only one assay method be used consistently to monitor each patient's course of therapy. This procedure does not provide serial monitoring; it is intended for one-time use only. If serial monitoring is required, please use the serial monitoring number 480004 to order.

Limitations

Used alone, alkaline phosphatase may be misleading.

LOINC map

Result codeResult nameUnitsResult LOINC
001107Alkaline PhosphataseIU/L6768-6

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 84075

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation