Labcorp test 001024, CPT 84100. Specimen: Serum (preferred) or plasma. Turnaround: Within 1 day.

Phosphorus is Labcorp test code 001024, billed with CPT 84100. Specimen: Serum (preferred) or plasma. Turnaround time: Within 1 day. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, Michigan Medicine Laboratories (MLabs), ARUP Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code001024 (Women's Health)
CPT84100
LOINC2777-1
SpecimenSerum (preferred) or plasma
Volume1 mL
Minimum volume0.7 mL ( Note: This volume does not allow for repeat testing.)
ContainerRed-top tube, gel-barrier tube, or green-top (lithium heparin) tube. Do not use oxalate, EDTA, or citrate plasma.
Turnaround timeWithin 1 day
Storage / transportMaintain specimen at room temperature.

Also known as: Inorganic Phosphate, Blood

Use

Causes of high phosphorus: Youth; exercise; dehydration and hypovolemia; high phosphorus content enema; acromegaly; hypoparathyroidism; pseudohypoparathyroidism; bone metastases; hypervitaminosis D; sarcoidosis; milk-alkali syndrome; liver disease, such as portal cirrhosis; catastrophic events such as cardiac resuscitation, pulmonary embolism, renal failure; diabetes mellitus with ketosis; serum artifact−sample not refrigerated; overheated, hemolyzed sample, or serum allowed to remain too long on the clot. Although phosphate accumulation occurs as renal disease progresses, hyperphosphatemia is not a feature of early renal failure; it does not usually develop before renal function has…

Methodology

Colorimetric

Collection instructions

Separate serum or plasma from cells within 45 minutes of collection.

Stability

TemperaturePeriod
Room temperature7 days
Refrigerated14 days
Frozen14 days
Freeze/thaw cyclesStable x3

Causes for rejection

Hemolysis; gross lipemia; improper labeling; unspun or improperly spun specimen

Reference range

See table. Age Male* (mg/dL) Female* (mg/dL) *LabCorp internal studies. 0 to 6 m 4.2–7.8 3.4–7.9 7 m to 1 y 4.0–6.8 4.0–6.8 2 to 19 y 3.4–5.5 3.3–5.1 >19 y 2.8–4.1 3.0–4.3

LOINC map

Result codeResult nameUnitsResult LOINC
001024Phosphorusmg/dL2777-1

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 84100

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation