Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Cleveland Clinic Laboratories › NTRK Next Generation Sequencing

NTRK Next Generation Sequencing: Cleveland Clinic Laboratories test NTRK

Cleveland Clinic Laboratories test NTRK, CPT 81194. Specimen: Block, Formalin fixed paraffin. Turnaround: 14 days.

NTRK Next Generation Sequencing is Cleveland Clinic Laboratories test code NTRK, billed with CPT 81194. Specimen: Block, Formalin fixed paraffin. Turnaround time: 14 days. Performing laboratory: Cleveland Clinic Laboratories, CLIA 36D0656094 (Cleveland, OH). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories.
LaboratoryCleveland Clinic Laboratories
CLIA number36D0656094
Test codeNTRK
CPT81194 - QTY (1)
LOINC—
SpecimenBlock, Formalin fixed paraffin
Volume10 mm square
ContainerSlides
Turnaround time14 days
Storage / transportAmbient

Also known as: NTRK Plus Gene Fusion NGS Panel

Methodology

Next Gen Sequencing

Stability

TemperaturePeriod
AmbientIndefinitely for FFPET slides. FFPET slides are transported at ambient temperature.
FrozenNot acceptable.
RefrigeratedNot acceptable.

Special instructions

Formalin-fixed paraffin-embedded tissue slides. Transport and store slides at ambient temperature. 10 unstained section FFPE tissue on charged, unbaked slides plus one H&E section with best tumor area circled by a pathologist.

Performed

Once per week

Collect Temperature

Ambient

Performing Laboratory

Cleveland Clinic Laboratories

View this test on Cleveland Clinic Laboratories's website → · Last checked 2026-11-29

Other tests billed with CPT 81194

Search the National Lab Test Directory · All Cleveland Clinic Laboratories tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation