Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › ARUP Laboratories › Preeclampsia Risk Assessment (sFlt-1/PlGF Ratio)

Preeclampsia Risk Assessment (sFlt-1/PlGF Ratio): ARUP Laboratories test 3017909

ARUP Laboratories test 3017909, CPT 0524U. Specimen: Serum separator tube (SST), plain red, or pink (K2EDTA). Turnaround: 1-3 days.

Preeclampsia Risk Assessment (sFlt-1/PlGF Ratio) is ARUP Laboratories test code 3017909, billed with CPT 0524U. Specimen: Serum separator tube (SST), plain red, or pink (K2EDTA). Turnaround time: 1-3 days. Performing laboratory: ARUP Laboratories, CLIA 46D0523979 (Salt Lake City, UT). Other labs in the directory with tests billed under the same CPT: Labcorp.
LaboratoryARUP Laboratories
CLIA number46D0523979
Test code3017909
CPT0524U
LOINC74757-6
SpecimenSerum separator tube (SST), plain red, or pink (K2EDTA)
Turnaround time1-3 days
Storage / transportPreferred transport temp: Refrigerated. Also acceptable: Frozen.

Also known as: Gestational hypertension; Hypertensive disorders of pregnancy; PlGF (Placental Growth Factor); Preeclampsia ratio; Preeclampsia risk; sFlt-1 (soluble fms-like tyrosine kinase 1); sFlt-1/PlGF Ratio

Use

This test is to be used in conjunction with other laboratory tests and clinical assessments to aid in the risk assessment of pregnant women (singleton pregnancies between gestational age 23+0 to 34+6/7 weeks) hospitalized for hypertensive disorders of pregnancy (preeclampsia, chronic hypertension with or without superimposed preeclampsia, or gestational hypertension) for progression to preeclampsia with severe features (as defined by American College of Obstetricians and Gynecologists guidelines) within 2 weeks of being tested.

Methodology

Quantitative Immunofluorescence

Collection instructions

Allow serum to clot completely at room temperature. Transfer 2 mL serum or plasma (Min: 0.5 mL) to an ARUP standard transport tube.

Stability

Room Temperature: 24 hours; Refrigerated: 1 month; Frozen: 1 month

Causes for rejection

Grossly hemolyzed, lipemic, and/or icteric specimens

Reference range

Test Number Components Reference Interval Preeclampsia sFlt-1/PlGF Ratio, S/P <40

Performed

Sun-Sat

Compliance Category

FDA

New York DOH Approval Status

This test is New York state approved.

LOINC map

Result codeResult nameUnitsResult LOINC
3018308Preeclampsia sFlt-1/PlGF Ratio, S/P74757-6

View this test on ARUP Laboratories's website → · Last checked 2026-11-29

Other tests billed with CPT 0524U

Search the National Lab Test Directory · All ARUP Laboratories tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation